2015-03-14 09:47:11 | |
| BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 15020858 |
| ADD: 525 PALM ST. SUITE B |
| CHANGE OF OCCUPANCY |
| CONT: TBD |
| TEL: (561)667-3661 |
| E-MAIL: [email protected] |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015 |
| ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| ELECTRONICALLY |
| UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| SUBMISSION OPTIONS ARE AS FOLLOWS: |
| 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL |
| SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| NAMING CONVENTION FOR EACH DOCUMENT |
| 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| AVAILABLE |
| |
| 1ST REVIEW |
| DATE: SAT. MARCH 14/ 2015 |
| ACTION: DENIED |
| |
| 1) PLEASE NOTE THIS IS A CHANGE OF OCCUPANCY AND WILL |
| REQUIRE ADDITIONAL INFORMATION FOR THE COMPLETION OF |
| THE CERTIFICATE OF OCCUPANCY. |
| |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION 107.3.5 MINIMUM PLAN |
| REVIEW CRITERIA FOR BUILDINGS. |
| 107.3.5.1 COMMERCIAL BUILDINGS: |
| 107.3.5.1.1 BUILDING |
| OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS |
| SHALL BE DETERMINED. PLEASE REVIEWOCCUPANCY LOAD/EGRESS |
| REQUIREMENTS SHALL INCLUDE: |
| OCCUPANCY LOAD |
| GROSS |
| NET |
| MEANS OF EGRESS |
| EXIT ACCESS |
| EXIT |
| EXIT DISCHARGE |
| STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION |
| DOORS |
| EMERGENCY LIGHTING AND EXIT SIGNS |
| SPECIFIC OCCUPANCY REQUIREMENTS |
| CONSTRUCTION REQUIREMENTS |
| HORIZONTAL EXITS/EXIT PASSAGEWAYS |
| MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE |
| TABLE 503). |
| BLDG. IS FIRE SPRINKLERED OR NOT |
| LIFE SAFETY SHALL BE DETERMINED AND SHALL INCLUDE THE |
| FOLLOWING ININFORMATION: |
| OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| OCCUPANCY LOAD |
| GROSS OR NET |
| MEANS OF EGRESS |
| EXIT ACCESS |
| EXIT |
| EXIT DISCHARGE |
| DOORS |
| SPECIFIC OCCUPANCY REQUIREMENTS :DAYCARE |
| CONSTRUCTION REQUIREMENTS MINIMUM BLDG TYPE |
| |
| 2) IN REVIEWING THESE PLANS THE 2010 FBC-B OCCUPANCY |
| LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| OCCUPANCY LOAD |
| GROSS |
| NET |
| MEANS OF EGRESS |
| EXIT ACCESS |
| EXIT |
| EXIT DISCHARGE |
| STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION |
| DOORS |
| EMERGENCY LIGHTING AND EXIT SIGNS |
| SPECIFIC OCCUPANCY REQUIREMENTS |
| CONSTRUCTION REQUIREMENTS |
| HORIZONTAL EXITS/EXIT PASSAGEWAYS |
| |
| 2) IN REVIEWING THESE PLANS THE OCCUPANCY |
| CLASSIFICATION IS DEFINED UNDER SECTION 2010 FBC-B |
| 303.1 EXCEPTION # 5. ACCESSORY RELIGIOUS EDUCATIONAL |
| ROOMS AND RELIGIOUS AUDITORIUMS WITH OCCUPANT LOADS OF |
| LESS THAN 100 ARE NOT CONSIDERED SEPARATE OCCUPANCIES. |
| THERE FOR THIS OCCUPANCY SHALL BE CLASSIFIED AS A A3 |
| OCCUPANCY. UNLESS THIS SAME EDUCATIONAL ROOMS WILL BE |
| USED AS A DAYCARE FACILITY DURING THE WORK WEEK. PLEASE |
| INDICATE AS SUCH, BECAUSE IT WILL THEN FALL UNDER THE |
| FBC-B CHAPTER 436 DAY-CARE OCCUPANCIES. NOTE IF THIS |
| AREA IS DAYCARE IT WILL BE CONSIDERED A MIXED USE |
| OCCUPANCY BETWEEN DAYCARE AND EDUCATIONAL, THE MOST |
| STRINGENT REQUIEMENTS OF EITHER OCCUPANCY WILL BE THE |
| CODE SECTION REQUIRED TO ACHIEVE. |
| |
| 3) IT IS ASSUMED THIS BUILDING IS NOT FIRE SPRINKLERED, |
| IN DOING SUCH WITH THE A3 OCCUPANCY 930 SQ FT/ 15= 62 |
| OCCUPANTS AND WILL REQUIRE 2 EXITS 1/2 THE DIAGONAL |
| DISTANCE OF THE ROOM APART. THE 1/2 THE DIAGONAL |
| DISTANCE IS APPROXIMATELY 26 FT APART AND THE DOORS ARE |
| ONLY 18 FT APART. PLEASE SEE THE 2010 FBC-B TABLE |
| 1015.1 WILL REQUIRED 2 EXITS SINCE THE OCCUPANT LOAD IS |
| GREATER THAN 49 OCCUPANTS. |
| |
| 4) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| JAMES WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: (561) 805-6715 |
| FAX: (561)805-6676 |
| E-MAIL: [email protected] |