2015-02-04 17:58:48****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE SOFFIT OPTION SELECTED HAS A DP LIMITATION OF
 +80 / -42.2PSF. IT APPEARS THAT THIS IS EXPOSURE D, AND
 MEAN ROOF HEIGHT NOT PROVIDED (MRH IS THE AVERAGE OF
 ROOF PEAK AND EAVE). PLEASE PROVIDE SO THAT DESIGN
 PRESSURES CAN BE DETERMINED.
  
 FOR 10SF (AREA TRIBUTARY TO A FASTENER), 20' MRH,
 EXPOSURE D, DESIGN PRESSURES REQUIRED ARE +48.5/-52.6
 FOR ZONE 4, AND +48.5/-65PSF FOR ZONE 5. PLEASE
 ADDRESS.
  