2015-02-06 07:56:11 | BUILDING PLAN REVIEW |
| PERMIT: 15010908 |
| ADD: 1097 THE POINT DR./ AKA/ |
| 1097 PARADISE COVE |
| CONT: HOME STRETCHERS INC. |
| TEL: (561) 588-1888 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: FRI. FEB. 06/2015 |
| ACTION: DENIED |
| |
| 1) THE DESIGNER OF RECORD HAS NOT DECLARED TO WHICH |
| METHOD THEY ARE GOING TO COMPLY TO THE 2010 FL EXISTING |
| BLDG CODE, 101.5. THE PERMIT APPLICATION INDICATES |
| REMOVAL OF DRYWALL, THE FLOOR PLAN SUBMITTED INDICATES |
| THE REMOVAL AND REPLACE DRYWALL THROUGH OUT THE ENTIRE |
| UNIT, DOES THIS INCLUDE THE CEILINGS? WPB ADMIN CODE |
| 107.2.1.3 ADDITIONAL INFORMAION IS REQUIRED. IS THIS |
| FROM A FIRE & SMOKE DAMAGE? |
| |
| 2) WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 107.3.5 MINIMUM PLAN |
| REVIEW CRITERIA FOR BUILDINGS. |
| 107.3.5.1 COMMERCIAL BUILDINGS: |
| 107.3.5.1.1 BUILDING |
| |
| 2.1) MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED |
| (SEE TABLE 503). |
| |
| |
| 2.2) FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL |
| INCLUDE THE FOLLOWING COMPONENTS: |
| FIRE-RESISTANT SEPARATIONS/ TENANT SEPARATION WALLS/ |
| PLANS INDICATE 2 HR FIRE RATING, PROVIDE UL OR GYPSUM |
| ASSOC ASSEMBLY NUMBER SEE FBC-B |
| 709.3. |
| |
| FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION |
| |
| PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS |
| |
| PROTECTION OF OPENINGS OF HORIZONTAL ASSEMBLIES/ FLOOR |
| CEILING ASSOCIATION |
| |
| FLOOR/ CEILING ASSEMBLY, CONCRETE/ METAL DECK OR A |
| FOOR/ CEILING ASSEMBLY, WOOD TRUSSES PROVIDE UL, OR |
| GYPSUM ASSEMBLY TO WHAT WILL BE |
| INSTALLED AND HOUR OF FIRE RATING. 2010 FBC-B 712.3 |
| FIRE-RESISTANCE RATING. THE FIRE-RESISTANCE RATING OF |
| FLOOR AND ROOF ASSEMBLIES SHALL NOT BE |
| LESS THAN THAT REQUIRED BY THE BUILDING TYPE OF |
| CONSTRUCTION. HORIZONTAL ASSEMBLIES SEPARATING DWELLING |
| UNITS IN THE SAME BUILDING AND HORIZONTAL |
| ASSEMBLIES SEPARATING SLEEPING UNITS IN THE SAME |
| BUILDING SHALL BE A MINIMUM OF 1-HOUR |
| FIRE-RESISTANCE-RATED CONSTRUCTION. |
| DOES THE DUCT WORK GO UP INTO THE FLOOR TRUSSES? IF SO |
| A 1 HR. BOXED CHASE WILL BE REQUIRED OR A RADIENT |
| DAMPER. 2010 FBC-B 713.4.1.3 DUCTS |
| AND AIR TRANSFER OPENINGS. PENETRATIONS OF HORIZONTAL |
| ASSEMBLIES BY DUCTS AND AIR TRANSFER OPENINGS SHALL |
| COMPLY WITH SECTION 716. |
| |
| 2.3 FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: SCHEMATIC |
| FIRE SPRINKLERS NFPA 13 OR NFPA 13R. |
| |
| 3) NOTE THE EXISTING DINING ROOM IS BEING TRANSFORMED |
| INTO A SLEEPING ROOM, PLEASE PROVIDE COMPLIANCE WITH |
| 2010 FBC-B 1029.2 EMERGENCY ESCAPE & RESCUE WINDOWS 5.7 |
| FOR 2ND OR 3RD FLOOR UNITS, 5 SQ FT FOR 1ST FLOOR UNITS |
| (VENT SIZE). PROVIDE THE OVER ALL WINDOW SIZE AND THE |
| TYPE OF WINDOW. |
| |
| 4) THE DEN BEING A NEW SLEEPING ROOM PLEASE PROVIDE |
| COMPLIANCE WITH THE 2010 FBC-B [F] 907.2.9 GROUP R-2. |
| FIRE ALARM SYSTEMS AND SMOKE ALARMS SHALL BE INSTALLED |
| IN GROUP R-2 OCCUPANCIES AS REQUIRED IN SECTIONS |
| 907.2.9.1 AND 907.2.9.2. |
| |
| 5) THE DESIGNER OF RECORD IT APPEARS TO BE THE |
| CONTRACTOR, WILL NEED TO PRINT THEIR NAME, SIGN THEIR |
| NAME AND PRINT THEIR LICENSE NUMBER ON THE PLANS THEY |
| ARE DESIGNING. 2010 WEST PALM BEACH AMENDMENTS TO THE |
| FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, |
| 107.3.4 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. |
| |
| 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| |
| IMPORTANT NOTICE: EFFECTIVE MARCH 2, 2015 |
| ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| ELECTRONICALLY |
| UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| SUBMISSION OPTIONS ARE AS FOLLOWS: |
| 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL |
| SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| NAMING CONVENTION FOR EACH DOCUMENT |
| 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| AVAILABLE |
| |
| |