2015-02-07 10:08:54 | BUILDING PLAN REVIEW |
| REVISION: 15010430 |
| PERMIT: 14040379 |
| ADD: 2101 OKEECHOBEE BLVD. |
| CONT: HEDRICK BROTHERS |
| TEL: (561)568-8931 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 1ST REVIEW |
| DATE: |
| ACTION: DENIED |
| |
| IMPORTANT NOTICE: EFFECTIVE MARCH 2, 2015 |
| ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| ELECTRONICALLY |
| UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| SUBMISSION OPTIONS ARE AS FOLLOWS: |
| 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL |
| SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| NAMING CONVENTION FOR EACH DOCUMENT |
| 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| AVAILABLE |
| |
| |
| 1A) A-101 & A-121 DETAILS 2 & 3 SHEET A-122 SHOWS NEW |
| CAR LIFTS, SHEET A-122 DETAIL 2 & 3 SHOW THESE LIFTS |
| WITH A PIT, THERE HAS BEEN NO STRUCTURAL |
| SHEETS IN THIS SUBMITTAL, NO DETAILS AS TO THE TYPE OF |
| LIFT, TRACTION OR HYDROLIC ETC. |
| |
| 1B) SHEET A-121 SHOWS THE FINISH FLOOR AS A FLOOR TILE, |
| A OIL SEPARATOR WAS NOT RREQUIRED BECAUSE OF THE |
| NON-ABSORBENT SURFACE OF THE TILE, THAT THE OILS AND |
| GREASE WERE TO BE CLEANED UP, THIS SHEET DOES NOT |
| INDICATE THE SURFACE FINISH OF THE AREA WALLS NOR |
| FLOOR. PLEASE PROVIDE COMPLIANCE WITH |
| 2010 FBC-B: 406.6.4 FLOOR SURFACE. |
| REPAIR GARAGE FLOORS SHALL BE OF CONCRETE OR SIMILAR |
| NONCOMBUSTIBLE AND NONABSORBENT MATERIALS. |
| EXCEPTION: SLIP-RESISTANT, NONABSORBENT, INTERIOR FLOOR |
| FINISHES HAVING A CRITICAL RADIANT FLUX NOT MORE THAN |
| 0.45 W/CM2, AS DETERMINED BY NFPA 253, SHALL BE |
| PERMITTED. |
| |
| |
| |
| |
| BUILDING PROVISO FROM ISSUED PLANS: |
| |
| 1) THE DESIGNER OF RECORD WOULD LIKE TO DEFER THE |
| PRODUCT APPROVALS AS A DEFERRED SUBMITTAL 2010 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1, ADMINISTRATION107.3.4.2. |
| 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 |
| COMPONENTS & CLADDING |
| |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| (31)(A) EXTERIOR DOORS. |
| (B) WINDOWS |
| (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| LOUVERS, EFIS SYSTEMS, RAINSCREEN PERFORATED CORRUGATED |
| METAL PANEL SYSTEM |
| (D) ROOFING PRODUCTS AND ASSEMBLIES |
| (E) PRE-ENGINEERED A/C STANDS |
| |
| 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |