Plan Review Notes
Plan Review Notes For Permit 15010404
Permit Number 15010404
Review Stop B
Sequence Number 1
Notes
Date Text
2015-01-26 11:26:06BUILDING PLAN REVIEW
 PERMIT: 15010404
 ADD: 255 EVERNIA ST. / SUITE # MU#3.
 CONT: BLUEWATER BUILDERS
 TEL: ( 954)753-7233
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE:MON. JAN. 26/ 2015
 ACTION: DENIED
  
 1) SHEET A251 CLASSIFICATION INDICATES THIS IS A LEVEL
 II ALTERATION. THIS IS A CHANGE OF USE. PLEASE REVIEW:
 2010 FL. EXISTING BUILDING CODE 01.2 CHANGE IN
 OCCUPANCY WITH NO CHANGE OF OCCUPANCY CLASSIFICATION.
 A CHANGE IN OCCUPANCY, AS DEFINED IN SECTION 202, WITH
 NO CHANGE OF OCCUPANCY CLASSIFICATION SHALL NOT BE MADE
 TO ANY STRUCTURE THAT WILL SUBJECT THE STRUCTURE TO ANY
 SPECIAL PROVISIONS OF THE APPLICABLE FLORIDA BUILDING
 CODE, INCLUDING THE PROVISIONS OF SECTIONS 902 THROUGH
 911, WITHOUT THE APPROVAL OF THE CODE OFFICIAL. A
 CERTIFICATE OF OCCUPANCY SHALL BE ISSUED WHERE IT HAS
 BEEN DETERMINED THAT THE REQUIREMENTS FOR THE CHANGE IN
 OCCUPANCY HAVE BEEN MET.
  
 2) SHEET A251 THE SQUARE FOOTAGE LISTED FOR THE
 BUSINESS OCCUPANCY 248 SQ. FT. AND ASSOCIATED OCCUPANT
 LOAD OF 2.48 OCCUPANTS. NOTE YOU ROUND UP TO THE NEXT
 WHOLE PERSON, THERE ARE NO PARTS OF A OCCUPANT. BOAF
 INFORMAL INTERPRETATION # 5479. 2010 FBC-B TABLE
 1004.1.1. ROUND UP ALL PARTIAL OCCUPANTS.
  
 3) SHEET A251 PLEASE DESIGNATE THE WORK AREA THAT WILL
 BE UNDER THE 248 SQ. FT. AREA, THE WORK OFFICE 101 IS
 LARGER THAN 248 SQ FT. PLEASE ALSO NOTE OFFICE # 105
 AND OR THE DEN # 104 TO BE USED FOR THE BUSINESS
 PORTION OF THE WORK/ LIVE LOFT UNIT. FBE-B 438.1.1(2)
 LIMITATIONS.
  
 4) THIS PLAN WILL NEED TO BE REVIEWED BY PALM BEACH
 COUNTY IMPACT FEE OFFICE FOR THE CHANGE OF USE TO
 ASSESS IF THERE ARE IMPACT FEES DUE.
 THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]