2015-04-25 06:38:12BUILDING PLAN REVIEW
 PERMIT: 15010402
 ADD: 255 EVERNIA ST # 1405
 CONT: BLUEWATER BUILDERS
 TEL: (954)753-7233
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: SAT. APRIL 25/ 2015
 ACTION: DENIED
  
 NOTICE!!!!!! WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
  
 NOTICE: SUBMIT TEST REPORTS TO THE DESIGNER OF RECORD
 FOR REVIEW BEFORE SUBMITTAL TO THE BUILDING DEPARTMENT.
  
 1) 2ND REQUEST, SUPPLY THE ASTM E-90 TEST REPORT FOR
 FLOOR INSULATION. SHEET A152 SHOWS AN EXISTING SINGLE
 ENTRY, SHEET A201 SHOWS A NEW PORTION OF THE CORRIDOR,
 A LOBBY AREA AND 2 NEW ENTRIES TO (2) NEW R2 UNITS. THE
 PLANS INDICATE EITHER A WALL IDENTIFICATION TAG 1 OR 2.
 SHEET A903 SHOWS BOTH WALLS AS 1 HOUR FIRE RATED WALLS,
 BOTH DETAILS ARE MISSING COMPLIANCE WITH:
 2010 FBC-B 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90. PENETRATIONS OR OPENINGS IN CONSTRUCTION
 ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED
 CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR
 EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED OR
 OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS.
 THIS REQUIREMENT SHALL NOT APPLY TO DWELLING UNIT
 ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT
 FITTING TO THE FRAME AND SILL.
  
 2) 2ND REQUEST, SUPPLY THE ASTM E-90 TEST REPORT FOR
 FLOOR INSULATION. SHEET A152 NOTE # 3 INDICATES TO
 REMOVE ALL FLOOR TILE AND GROUT. SHEET A202 SHOW NEW
 FLOOR TILE BUT THERE IS NO NOTES ABOUT THE FLOOR
 FINISHES. PLEAS PROVIDE COMPLIANCE WITH :
 2010 FBC-B 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 3) 2ND REQUEST SUPPLY THE TEST REPORT FOR FLAME SPREAD.
 2010 FBC-B 603.2.EXCEPTION (2) INSULATION INSTALLED
 BETWEEN A FINISHED FLOOR AND SOLID DECKING WITHOUT
 INTERVENING AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME
 SPREAD INDEX OF NOT MORE THAN 200.
  
 4) COMPLIED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]