2015-04-25 06:31:41 | BUILDING PLAN REVIEW |
| PERMIT: 15010400 |
| ADD: 255 EVERNIA ST # 1404 |
| CONT: BLUEWATER BUILDERS |
| TEL: (954)753-7233 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: SAT. APRIL 25/ 2015 |
| ACTION: DENIED |
| |
| NOTICE!!!!!!WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| NOTICE: SUBMIT TEST REPORTS TO THE DESIGNER OF RECORD |
| FOR REVIEW BEFORE SUBMITTAL TO THE BUILDING DEPARTMENT. |
| |
| |
| 1) 2ND REVIEW, PROVIDE ACTUAL TEST IN COMPLIANCE WITH |
| ASTM E 90 FOR FLOOR INSULATION. SHEET A152 SHOWS AN |
| EXISTING SINGLE ENTRY, SHEET A201 SHOWS A NEW PORTION |
| OF THE CORRIDOR, A LOBBY AREA AND 2 NEW ENTRIES TO (2) |
| NEW R2 UNITS. THE PLANS INDICATE EITHER A WALL |
| IDENTIFICATION TAG 1 OR 2. SHEET A903 SHOWS BOTH WALLS |
| AS 1 HOUR FIRE RATED WALLS, BOTH DETAILS ARE MISSING |
| COMPLIANCE WITH: |
| 2010 FBC-B 1207.2 AIR-BORNE SOUND. |
| WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| E 90. PENETRATIONS OR OPENINGS IN CONSTRUCTION |
| ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED |
| CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR |
| EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED OR |
| OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS. |
| THIS REQUIREMENT SHALL NOT APPLY TO DWELLING UNIT |
| ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT |
| FITTING TO THE FRAME AND SILL. |
| |
| 2) 2ND REVIEW, PROVIDE ACTUAL TEST IN COMPLIANCE WITH |
| ASTM E 90 FOR FLOOR INSULATION. SHEET A152 NOTE # 3 |
| INDICATES TO REMOVE ALL FLOOR TILE AND GROUT. SHEET |
| A202 SHOW NEW FLOOR TILE BUT THERE IS NO NOTES ABOUT |
| THE FLOOR FINISHES. PLEASE PROVIDE COMPLIANCE WITH : |
| 2010 FBC-B 1207.3 STRUCTURE-BORNE SOUND. |
| FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| |
| 3) 2ND REVIEW, PROVIDE ACTUAL TEST IN COMPLIANCE WITH |
| ASTM E 90 FOR FLOOR INSULATION. 2010 FBC-B |
| 603.2.EXCEPTION (2) INSULATION INSTALLED BETWEEN A |
| FINISHED FLOOR AND SOLID DECKING WITHOUT INTERVENING |
| AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX |
| OF NOT MORE THAN 200. |
| |
| 4) COMPLIED. |
| |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |