Plan Review Notes For Permit 15010156 |
Permit Number |
15010156 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2015-01-27 18:29:04 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | | | 1. FBC 2010 EXISTING BUILDING 602.4, FBC 2010 | | RESIDENTIAL 311.7.4.3, OPEN RISERS ARE PERMITTED, | | PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT | | PERMIT THE PASSAGE OF A 4-INCH DIAMETER SPHERE. | | | | UPON REQUEST, THIS CAN BE A PROVISO ITEM. SUBJECT TO | | THE FIELD INSPECTOR'S DISCRETION, A REVISION MAY BE | | REQUIRED. | | | | |
|