Plan Review Notes
Plan Review Notes For Permit 14120886
Permit Number 14120886
Review Stop E
Sequence Number 1
Notes
Date Text
2015-01-12 12:59:151/12/2015
 PROJECT: EARTHLINK
 PERMIT#: 14120886
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) FBC- 107.3.5.3. PROVIDE A DETAILED ELECTRICAL
 SERVICE DISTRIBUTION SYSTEM TO INCLUDE THE FOLLOWING: A
 RISER DIAGRAM WITH A GROUNDING ELECTRODE SYSTEM, ALL
 SERVICE DISCONNECTS, AND PANELS, ALL CONDUIT AND WIRE
 SIZES, A COMPLETE DETAILED LOAD CALCULATION(S), CLEAR
 AND SPECIFIC PANEL DIRECTORIES, AND ALL CIRCUIT NUMBERS
 AS INDICATED ON THE PANEL DIRECTORIES TO BE SHOWN ON
 THE ELECTRICAL FLOOR, AND CELING LIGHTING PLANS. THE
 RISER DIAGRAM SUBMITTED IS INCOMPLETE.INDICATE AND
 INCLUDE ON THE REVISED RISER DIAGRAM ALL UTILITY
 SERVICE ENTRANCE CONDUIT AND WIRE SIZES, MAIN
 DISCONNECTS, PANELS, FEEDERS, AND GROUNDING ELECTRODE
 SYSTEM ASSOCIATED WITH THE SUITE UNDER CONSTRUCTION
 ONLY. INDICATE AND DISDINGUISH BETWEEN WHAT IS EXISTING
 TO REMAIL, WHAT IS EXISTING TO BE RELOCATED, AND WHAT
 IS PROPOSED TO BE NEW. WITH THE LOAD CALCULATION
 INDICATE WHAT IS THE EXISTING LOAD AND WHAT IS PROPOSED
 TO BE ADDED, AND THE NEW TOTAL CONNECTED LOAD.
  
 2) VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS
 HAS A FAULT CURRENT RATING THAT IS SUFFICIENT AT
 NOMINAL CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE
 INTERRUPTED. NEC 110.9
  
 3) PROVIDE SAFETY LABELING FOR ARC FLASH PROTECTION FOR
 THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. NEC
 110.16, 110.22
  
 4) PROVIDE THE LOCATION OF THE ELECTRICAL SERVICE AND
 EACH OF THE ELECTRICAL PANELS. FOR THE PANEL THAT IS
 BEING RELOCATED, PROVIDE BOTH THE OLD EXISTING LOCATION
 AND THE NEW RELOACTED LOCATION ON THE ELECTRICAL FLOOR
 PLAN.
  
 SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY
 MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS
 ARE REQUIRED FOR SITE LIGHTING, GENERATORS. FIRE ALARM,
 ACCESS CONTROL SYSTEM, SECURITY, CCTV, NETWORK, DATA,
 AND, COMMUNICATION AS NEEDED. NOT ALL MAY BE UTILIZED
 OR RQUIRED ON THIS PROJECT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved