Plan Review Notes
Plan Review Notes For Permit 14120732
Permit Number 14120732
Review Stop B
Sequence Number 2
Notes
Date Text
2015-03-07 13:14:51****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
  
 1. OK
  
 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND
 OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%.
  
 TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION
 NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT:
  
 STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS
 - AWNING, CASEMENT, SINGLE HUNG?
  
 STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE.
 CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE
 WINDOW IS FULLY OPEN.
  
 3. NEW COMMENT - IT IS NOT POSSIBLE TO DETERMINE
 CORRELATE THE PRODUCT APPROVALS WITH THE OPENINGS. FOR
 INSTANCE:
  
 PRODUCT APPROVAL 14610.5 VINYL HORIZONTAL ROLLER NON
 IMPACT HAS "WINDOW #3" WRITTEN ON IT, BUT OPENING #3
 DOES NOT HAVE SHUTTERS PROPOSED.
  
 14610.6 AND 17472.2 ARE IMPACT PRODUCTS, "W-3" WRITTEN
 ON BOTH.
  
 REVISE THE FLOOR PLAN TO INDICATE TYPE OF WINDOW
 PROPOSED (CORRELATE WITH THE PRODUCT APPROVAL),
 INDICATE LOCATION OF THE IMPACT WINDOWS. PROVIDE THE
 SIZES OF ALL OPENIINGS AND THE ADDITIONAL INFORMATION
 REQUIRED FOR BEDROOM WINDOWS AS INDICATED IN ITEM #2.
  
 THE PAGE PROVIDED PREVIOUSLY NO LONGER CORRELATES WITH
 THE NEW FLOOR PLAN AND PRODUCT APPROVALS PROVIDED. FOR
 INSTANCE, OPENING #3 ON THE CHART PROVIDED IN FIRST
 SUBMITTAL STATES THAT FL1850 R9 IS PROPOSED, NOT
 CONSISTENT WITH THE NEW INFORMATION.
  
  
  