2015-06-04 09:54:49 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 14120431 |
| ADD: 312 23RD ST. |
| PCN:74-43-43-10-19-003-0143 |
| CONT: PETROCCHI CONSTRUCTION |
| TEL: (305)495-3745 |
| E-MAI: [email protected] |
| |
| PARK PALM BEACH MULTIFAMILY RESIDENTIAL |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| 3RD REVIEW |
| DATE: FRI. MAY 29TH/ 2015 |
| ACTION: DENIED |
| NOTICE: ART IN PUBLIC PLACES |
| THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES |
| ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR |
| NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT |
| APPLICATION WAS SUBMITTED AFTER 7/1/14, AND THE TOTAL |
| PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN |
| $500,000. PER CITY OF WEST PALM BEACH ORDINANCE NO. |
| 4504-14, AND CITY OF WEST PALM BEACH CODE OF |
| ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION |
| 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS |
| 1% OF THE TOTAL PROJECT CONSTRUCTION COST. |
| |
| PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE |
| V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND |
| NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO |
| THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE |
| PROJECTS |
| |
| 1) COMPLIED. |
| 2) THIS PROJECT IS FOR A 4 STORY BUILDING THAT |
| QUALIFIES AS A THRESHOLD BUILDING. FL S. S. 553.71(7) " |
| THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS |
| GREATER THAN (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH |
| HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN |
| THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. |
| IN AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 |
| PERSONS. |
| 2A) 2ND. COMPLIED, WRITTEN INSPECTION PLAN. |
| 2B)SEMI- COMPLIED. THE SPECIAL INSPECTION FORMS WERE |
| PARTIALLY FILLED OUT AND SIGNED , THE CONTRACTOR PAGE # |
| 5 HAS NOT BEEN FILLED OUT. |
| |
| 2C) COMPLIED REQUEST. SPECIAL INSPECTOR RESUME' . |
| 2D) 3RD REQUEST. RESPONSE, OWNER WILL SUBMIT. THE |
| CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY FOR |
| THIS TYPE OF CONSTRUCTION. THIS MAY BE SUBMITTED TO KEN |
| CONRAD BY E-MAIL. KEN CONRAD: [email protected] |
| 2E) NOTE NO ACTION IS REQUIRED, WE ARE E-MAILING YOU |
| THE THRESHOLD INSPECTOR DOCUMENTS AND FORMS TO THIS |
| E-MAIL ADDRESS; E-MAIL: [email protected] |
| JAN. 20/2015 |
| 2F) NOTICE: THIS IS A DIGITAL PLAN, AFTER PERMIT |
| ISSUANCE, THE PERMIT LIBRARIAN WILL E-MAIL YOU, THE |
| APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR |
| PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN |
| COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR |
| THE MEP INSPECTORS. |
| 2G) NOTICE TO THRESHOLD INSPECTOR & CONTRACTOR. PLEASE |
| CALL THE CITY OF WEST PALM BEACH?S AUTOMATED TELEPHONE |
| INSPECTIONS LINE (561) 805-6700) FOR IN-PROGRESS |
| INSPECTIONS FOR AUDITING OF JOBSITE INSPECTIONS. |
| 2H) NOTICE: REQUEST. RESPONSE INFORMATIONAL ONLY, |
| PLEASE INCORPORATE INTO THE PLANS UNDER FIRE STOPPING |
| PENETRATIONS. 109.3.6 THRESHOLD BUILDINGS, OPERATING |
| GUIDELINES FOR THRESHOLD INSPECTORS #26. ASSURE THAT |
| THE DESIGNER HAS REQUIRED ON THE PLANS OR |
| SPECIFICATIONS ONE MATERIAL, APPROVED FOR FIRE STOPPING |
| PENETRATIONS, FOR WALLS AND CEILINGS. |
| 3) MISSING THE REVISED COST CALCULATION SHEET. |
| RESPONSE SEE RESPONSE FROM OWNER AND CONTRACTOR, WHERE. |
| THE PERMIT VALUATION OF $8,500,000.00 IS LOW COMPARED |
| TO THE CALCULATED VALUE FROM THE ICC BUILDING VALUATION |
| DATA AUGUST 2014 USING THESE TABLES THE CALCULATED |
| VALUE OF $9,855,203.00. PLEASE NOTE ANY SUB-PERMIT THAT |
| TAKES SEPARATE FEES AND REVIEWS PLEASE LIST PERMITS AND |
| VALUES, THESE WILL BE DEDUCTED FROM THE PRIME VALUE. |
| ANY PERMITS AND VALUES NOT INCLUDED IN THIS LIST WILL |
| REQUIRE SEPARATE FEES & REVIEWS. |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION 108.3* BUILDING PERMIT |
| VALUATION. |
| IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| CONGRESS. |
| 4) COMPLIED. SOILS REPORT. |
| |
| 5)COMPLIED. PAGE 003/ A-1.00 CODE SUMMARY SHEET: |
| |
| |
| |
| 6-18) COMPLIED. PROVISO: DEFERRED SUBMITTAL. CONTRACTOR |
| SHALL SUBMIT FLOOR INSULATION IN ACCORDANCE WITH: |
| FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. FLOOR/CEILING |
| ASSEMBLIES BETWEEN DWELLING UNITS OR BETWEEN A DWELLING |
| UNIT AND A PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE |
| SHALL HAVE AN IMPACT INSULATION CLASS (IIC) RATING OF |
| NOT LESS THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN |
| ACCORDANCE WITH ASTM E 492. |
| |
| FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND. |
| WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| E 90. |
| |
| FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2. |
| INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. |
| |
| FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| |
| |
| 19) COMPLIED. GUARD RAIL & ATTACHMENT |
| |
| 20-22) COMPLIED |
| |
| 23) BUILDING PROVISO: DEFERRED SUBMITTALS. 107.3.4.2 |
| CELCORE LIGHTWEIGHT INSULATING CONCRETE NOA 13-0307.02 |
| CIRCLE THE SUB-SYSTEM THAT IS TO BE USED ON THIS |
| PROJECT AND THE ASSOCIATED PRESSURES. 107.2.1.3 |
| ADDITIONAL INFORMATION IS REQUIRED. 107.2.1.2 FOR ROOF |
| ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION |
| DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE |
| TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING |
| REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE |
| RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT |
| EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE |
| WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE |
| OR A STATEMENT BY AN ARCHITECT OR ENGINEER FOR THE |
| SPECIFIC SITE MUST BE SUBMITTED WITH THE CONSTRUCTION |
| DOCUMENTS. |
| |
| 24-27)BUILDING PROVISO: DEFERRED SUBMITTALS. 107.3.4.2 |
| DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, |
| DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF |
| THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE |
| APPLICATION AND THAT ARE TO BE SUBMITTED TO THE |
| BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL |
| OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF |
| THE BUILDING OFFICIAL. THE REGISTERED DESIGN |
| PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE |
| DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR |
| REVIEW BY THE BUILDING OFFICIAL. |
| DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO |
| THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL |
| ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED |
| SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING |
| OFFICIAL. |
| |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| (31)(A) EXTERIOR DOORS. |
| (B) WINDOWS |
| (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| LOUVERS, EFIS SYSTEMS, |
| (D) ROOFING PRODUCTS AND ASSEMBLIES |
| (E) SHUTTERS |
| (F) SKYLIGHTS |
| (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C |
| STANDS |
| |
| 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |