2014-12-22 16:43:23 | BUILDING PLAN REVIEW |
| PERMIT: 14120265 |
| ADD: 205 DATURA ST. |
| CONT: SMITHCO WPB INC. |
| TEL: (561)633-3793 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: MON. DEC. 22/2014 |
| ACTION: DENIED |
| |
| 1) SHEET H02.01 INDICATES AN ALTERNATE LOCATION FOR THE |
| ACCU-1, ACCU-2 & ACCU-3 UNITS IN THE ALLEY WAY. THERE |
| ARE (2) ISSUES; |
| |
| 1A) SUCH DRAWINGS AND SPECIFICATIONS SHALL CONTAIN |
| INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO |
| THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO |
| CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION |
| SHALL BE SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE |
| CITED AS A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" |
| OR ITS EQUIVALENT OR ALTERNATE BE USED AS A SUBSTITUTE |
| FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, |
| SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE |
| DESIGN. (SEE ALSO SECTION 107.3.5). |
| |
| 1B) IF THE DESIGNER DOES DECIDE TO PLACE THE ACCU UNITS |
| IN THE ALLEY WAY PLEASE PROVIDE WHERE THE PROPERTY LINE |
| IS LOCATED AND AT WHATIS THE DISTANCE FROM GRADE TO THE |
| BOTTOM OF THE FRAMEWORK OF THE UNIT. PLEASE SHOW CODE |
| COMPLIANCE WITH THE 2010 FBC-B 3202.3.2 WINDOWS, |
| BALCONIES, ARCHITECTURAL FEATURES AND MECHANICAL |
| EQUIPMENT. WHERE THE VERTICAL CLEARANCE ABOVE GRADE TO |
| PROJECTING WINDOWS, BALCONIES, ARCHITECTURAL FEATURES |
| OR MECHANICAL EQUIPMENT IS MORE THAN 8 FEET (2438 MM), |
| 1 INCH (25 MM) OF ENCROACHMENT IS PERMITTED FOR EACH |
| ADDITIONAL 1 INCH OF CLEARANCE ABOVE 8 FEET, BUT THE |
| MAXIMUM ENCROACHMENT SHALL BE 4 FEET. |
| |