2015-03-10 07:59:24 | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING |
| REVIEW COMMENTS. |
| CODE: 2010 BC. |
| |
| 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| DCA RULE 9N-3 FOR: |
| A) ROOF TILE AS SPECIFIED ON PLANS. (REPEAT COMMENT. |
| NOT ADDRESSED). |
| |
| B) ROOF TILE ADHESIVE IF SPECIFIED BY THE DESIGNER OF |
| RECORD. SEE ROOFF TILE NOA FOR LISTED ADHESIVE. (REPEAT |
| COMMENT. NOT ADDRESSED). |
| |
| C) FLAT ROOF AS SPECIFIED ON PLANS. AND IDENTIFY |
| APPROVED ASSEMBLY TO BE INSTALLED AND PROVIDE SIGNED |
| AND SEALED RAS 117 CALCULATIONS IF DESIGN PRESSURES ON |
| SELECTED ASSEMBLY DON'T MEET THE DESIGN PRESSURES OF |
| SEC. R301 OF 2020 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT |
| ADDRESSED). |
| |
| D) COPPER ROOF AS SPECIFIED ON PLANS. (REPEAT COMMENT. |
| NOT ADDRESSED). |
| |
| E) GARAGE DOORS SIZE AND TYPE AS SPECIFIED ON PLANS. |
| (REPEAT COMMENT. NOT ADDRESSED). |
| |
| G) ALL WINDOW TYPES AS SPECIFIED ON PLANS. (REPEAT |
| COMMENT. NOT ADDRESSED). |
| |
| H) ALL WINDOW MULLIONS AS SHOW ON PLANS. AND, CLEARLY |
| IDENTIFY MULLION SIZE TO VERIFY DESIGN PRESSURES. |
| (REPEAT COMMENT. NOT ADDRESSED). |
| |
| I) ALL EXTERIOR DOOR TYPES AND SIZES AS SPECIFIED ON |
| PLANS. (REPEAT COMMENT. NOT ADDRESSED). |
| |
| J) DOORS SHOWN ON SHEET A-2 ON THE LOGGIA BETWEEN |
| GARAGE AND MAIN HOUSE. (REPEAT COMMENT. NOT ADDRESSED). |
| |
| K) CUSTOM MAHOGANY ENTRY DOOR SIZE AND TYPE AS SHOWN ON |
| PLANS. (REPEAT COMMENT. NOT ADDRESSED). |
| |
| L) BALCONY FLOOR ASSEMBLY SPECIFIED ON PLANS. (REPEAT |
| COMMENT. NOT ADDRESSED). |
| |
| M) ALL STRUCTURAL CONNECTORS SPECIFIED ON THE |
| STRUCTURAL PLANS AND DETAILS. THIS COMMENT WAS |
| PARTIALLY ADDRESSED. ONLY THE FLORIDA PRODUCT APPROVAL |
| NUMBERS WERE GIVEN ON THE ROOF TRUSS CONNECTOR SCHEDULE |
| ON SHEET S-4. NEED THE FLORIDA PRODUCT APPROVAL NUMBER |
| LISTED NEXT TO EACH SPECIFIED CONNECTOR IN ALL DETAILS |
| AND SPECIFICATIONS SHOWN ON PLANS. |
| |
| N) GABLE END VENTILATION LOUVERS SHOWN ON PROPOSED |
| ELEVATIONS. |
| |
| O) PRECAST LINTELS AS SPECIFIED ON BEAM SCHEDULE ON |
| SHEET S-4. |
| |
| 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ALL THE PRODUCT APPROVALS. |
| SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC. |
| |
| 3- ENERGY CALCULATIONS SUBMITTED: |
| A) OWNER/AGENT O SING AND DATE BOTTOM OF FORM. SEC. |
| 103.2.3.2 OF 2010 FBC-ENERGY CONSERVATION. |
| |
| B) CONDITIONED FLOOR AREA ON ITEM #6 DOESN'T MATCH |
| PLANS. SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. |
| |
| C) COORDINATE ALL CEILINGS, WALLS, FLOOR INSULATION |
| WITH INFORMATION SHOWN ON PLANS. SEC. 103.2.2 OF 2010 |
| FBC-ENERGY CONSERVATION. |
| |
| D) ITEM #13 SHOWS ONLY ONE HEATING SYSTEM (SYS#1). NEED |
| HEATING FOR ALL HABITABLE ROOMS. SEC. R303.8 OF 2010 |
| FBC-RESIDENTIAL. |
| |
| E) REVISE TYPE OF ROOF AND ROOF MATERIALS ON PAGE 2 OF |
| 6 TO MATCH PLANS. SEC. 103.2.2 OF 2010 FBC-ENERGY |
| CONSERVATION. |
| |
| F) REVISE ALL WALL TYPES ON PAGE 3 OF 6 TO MATCH WALL |
| TYPES SHOWN PLANS. SEC. 103.2.2 OF 2010 FBC-ENERGY |
| CONSERVATION. |
| |
| G) COMPLETE ALL THE INFORMATION ON TOP OF FORM, |
| INCLUDING OWNER, BUILDER, PERMIT OFFICE AND |
| JURISDICTION #. SEC. 103.2.1.1.2 OF 2010 FBC-ENERGY |
| CONSERVATION. |
| |
| 4) DESIGNER OF RECORD TO PROVIDE COMPLETE DETAILS AND |
| SPECIFICATIONS SHOWING HOW THE R30 BUTT INSULATION IS |
| GOING TO BE INSTALLED BELOW THE ROOF SHEATHING AS SHOWN |
| ON PLANS. SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. |
| |
| 5) DESIGNER OF RECORD TO PROVIDE COMPLETE DETAILS AND |
| SPECIFICATIONS SHOWING COMPLIANCE WITH THE ROOF |
| VENTILATION. SEC. R806 OF 2010 FBC-RESIDENTIAL. |
| COORDINATE WITH THE ENERGY CALCULATIONS. |
| |
| 6) DEMOLITION NOTES ON SHEET S-1, SHEET A-1, SHEET A-3, |
| SHEET A-5: |
| A) REVISE NOTE #1. THERE ARE NOT 2009 SUPPLEMENTS TO |
| THE 2010 FBC. SEC. 107.2.1 CITY AMENDMENTS. (REPEAT |
| COMMENT. NOT ADDRESSED). |
| |
| B) PROVIDE THE NAME OF THE ARCHITECT MENTIONED ON NOTE |
| #4. AND PLANS NEED TO BE PROPERLY SIGNED AND SEALED AS |
| REQUIRED BY CHAPTER 481 FL. ST. (REPEAT COMMENT. NOT |
| ADDRESSED). |
| |
| 7- REVISE GENERAL NOTES #1 AND #2 ON SHEET A-2. THE |
| CORRECT CODE IS 2010 (NOT 20010) AND IS CITY OF WEST |
| PALM BEACH (NOT TOWN). (REPEAT COMMENT. NOT ADDRESSED). |
| SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 8- PROVIDE COMPLETE ENGINEER DETAILS AND SPECIFICATIONS |
| FOR BEARING PARTITION TO BE REMOVED AS SPECIFIED ON |
| SHEET A-1. SEC. R301 OF 2010 FBC-RESIDENTIAL AND SEC. |
| 107.2.1.3 CITY AMENDMENTS. |
| ***NOTE: ALSO, PROVIDE COMPLETE ENGINEERING DETAILS AND |
| SPECIFICATIONS INCLUDING SHORING DETAILS AND |
| SPECIFICATIONS FOR INTERIOR AND EXTERIOR WALLS ON FIRST |
| FLOOR TO BE DEMOLISHED. (REPEAT COMMENT. NOT |
| ADDRESSED). |
| |
| 9- EXISTING HOUSE WAS DESIGNED FOR ROOF SHINGLES. |
| PROVIDE ENGINEERING ANALYSIS SHOWING THAT EXISTING |
| STRUCTURE IS ADEQUATE TO TAKE THE ADDITIONAL LOAD OF |
| CONCRETE ROOF TILES. SEC. 107.2.1.3 CITY AMENDMENTS. |
| (REPEAT COMMENT. NOT ADDRESSED). |
| |
| 10- SHEET A-1: STAIRWAY NOTE STATES "STAIR TO |
| REMAIN/RAILING TO BE REPLACED". PROVIDE COMPLETE |
| DETAILS AND SPECIFICATIONS FOR THE NEW HANDRAIL AND |
| GUARDRAIL SHOWING COMPLIANCE WITH TABLE R301.5 AND SEC. |
| R311.7.7 AND R312 OF 2010 FBC-RESIDENTIAL. (REPEAT |
| COMMENT. NOT ADDRESSED). |
| |
| 11- THIS PROPERTY IS LOCATED IN FLOOD ZONE A5 WITH A |
| BASE FLOOD ELEVATION OF 7"-0" . CITY ORDINANCE REQUIRES |
| FINISH FLOOR ELEVATION TO BE 6" ABOVE BASE FLOOR |
| ELEVATION. THE FINISH FLOOR ELEVATION SHOWN ON ALL |
| PLANS DON'T MATCH. (REPEAT COMMENT) REVISE ALL OF THEM |
| TO MATCH. NEED COMPLETE AND CORRECT INFORMATION TO |
| VERIFY COMPLIANCE WITH FLOOD RESISTANT CONSTRUCTION |
| SEC. R322 OF 2010 FBC-RESIDENTIAL. |
| ***NOTE: SEE SAMANTA HILL COMMENTS ON DEMOLITION |
| PERMIT. #14120500. |
| |
| 12- PROVIDE DETAILS AND SPECIFICATIONS FOR THE FLAT |
| ROOF SLOPE SHOWING COMPLIANCE WITH SEC. R905.11.1 OF |
| 2010 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED). |
| |
| 13- DESIGNER OF RECORD TO PROVIDE |
| DETAILS/SPECIFICATIONS FOR THE ROOF ASSEMBLIES, |
| INCLUDING ROO TILE FASTENING AS REQUIRED BY SEC. |
| 107.2.1.2 CITY AMENDMENTS. IF USING SCREWS, THEN |
| SPECIFY SIZE AND NUMBER OF SCREWS. (REPEAT COMMENT. NOT |
| ADDRESSED). |
| |
| 14- SHEET A-7: NEW COVERED ENTRY ROOF DOESN'T MATCH |
| PROPOSED ROOF ON SHEET A-6. IT'S MISSING THE RIDGE. |
| REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY |
| AMENDMENTS. (REPEAT COMMENT. NOT ADDRESSED). |
| |
| 15- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| PROPOSED ROOF VENTILATION SHOWN ON GABLE ENDS ON SHEET |
| A-8. AND PROVIDE COMPLETE DETAILS AND SPECIFICATIONS |
| FOR CROSS VENTILATION FOR ALL ROOFS TO SHOW COMPLIANCE |
| WITH SEC. R806 OF 2010 FBC-RESIDENTIAL. (REPEAT |
| COMMENT. NOT ADDRESSED). |
| |
| 16- SECTION 2 ON SHEET A-11: REVISE THE ROOF SHEATHING |
| SPECIFICATION. NEED SOLID ROOF SHEATHING OR PROVIDE |
| COMPLIANCE WITH THE DESIGN AND TESTING REQUIRED BY SEC. |
| R905.3.1 OF 2010 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT |
| ADDRESSED). |
| |
| 17- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOM |
| SHOWING COMPLIANCE WITH SEC. R315 OF 2010 |
| FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED). |
| ***NOTE: IDENTIFY ON PLANS SPECIFIC LOCATION FOR EACH |
| REQUIRED ALARM. |
| |
| 18- PROPERTY IS LOCATED IN FLOOD ZONE A5. THE BASE |
| FLOOD ELEVATION IS 7.0'. THE MIN. FINISHED FLOOR |
| ELEVATION REQUIRED FOR THE NEW ADDITION, EXISTING HOUSE |
| AND EQUIPMENT IS 7.6'. ELEVATION CERTIFICATES WILL BE |
| REQUIRED DURING CONSTRUCTION. SEC. R322 AND SEC. AND |
| CITY CODE SEC. 94-546. |
| ***NOTE: DRAWINGS SUBMITTED SHOW FINSIHED FLOOR |
| ELEVATION OF MAIN HOUSE @ 8.15' NGVD. PROVIDE COPY OF |
| SURVEY SHOWING THE FINISHED FLOOR ELEVATIONS OF |
| EXISTING AND PROPOSED STRUCTURE AND EQUIPMENT. |
| COORDINATE FINISH FLOOR ELEVATIONS ON ALL PLANS. |
| |
| 19- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| BALCONY DECK CONSTRUCTION ASSEMBLY. SEC. R301.1 OF 2010 |
| FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED). |
| |
| 20- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| BALCONY GUARDRAILS SHOWING COMPLIANCE WITH THE LIVE |
| LOADS OF TABLE R301.5 AND REQUIREMENTS OF SEC. R312 OF |
| 2010 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED). |
| ***NOTE: DIMENSIONS SHOWN ON BALCONY DETAIL C/A-13 |
| DON'T COMPLY WITH SEC. R312. |
| |
| 21- PROVIDE COMPLETE MANUFACTURER SPECIFICATIONS FOR |
| THE FIREROCK NON VENTED FIREPLACE SHOWING COMPLIANCE |
| WITH TESTING IN ACCORDANCE WITH UL 127 AS REQUIRED BY |
| SEC. R1004 OF 2010 FBC-RESIDENTIAL. |
| ***NOTE: DESIGNER OF RECORD TO REVIEW AND APPROVE SPECS |
| PRIOR TO SUBMITTAL. (REPEAT COMMENT. NOT ADDRESSED). |
| |
| 22- NEW COMMENT: ARCHITECTURAL PLANS AND ENGINEER PLANS |
| DON'T MATCH. FOR EXAMPLE ROOF OVER PROPOSED LOGGIA IS |
| DIFFERENT. REVISE AND COORDINATE ALL PLANS AS REQUIRED |
| TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 23- NEW COMMENT: NEW ENGINEER'S DRAWINGS SHOW GARAGE |
| WITH A FINISHED FLOOR ELEVATION OF 6'-10". THE MINI. |
| FINISHED FLOOR ELEVATION REQUIRED IS 7'-6". OTHERWISE |
| SHOW COMPLIANCE WITH THE REQUIREMENTS OF FLOOD |
| -RESISTANT CONSTRUCTION OF SEC. R322 OF 2010 |
| FBC-RESIDENTIAL. |
| |
| 24- ENGINEER TO PROVIDE COMPLETE SECTION/DETAIL THRU |
| THE PROPOSED LOGGIA COLUMN FOOTINGS AND STEPS AND AND |
| EXISTING POOL. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 25- SHEET S-4: |
| A) WIND LOAD SCHEDULE TABLE: |
| (1) WHAT'S (4:12). IS THIS THE ROOF PITCH?. IF SO, IT |
| DOESN'T MATCH ARCHITECTURAL PLANS. REVISE AS REQUIRED |
| TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. |
| (2) REVISE THE ROOF WIND LOADS. THEY DON'T CORRESPOND |
| TO EXPOSURE "D" ACCORDING TO THE MEAN ROO HEIGHT OF THE |
| HOUSE. SEC. R301 OF 2010 FBC_RESIDENTIAL. |
| (3) REVISE THE WALL WIND LOADS. WHY THE TRIBUTARY AREA |
| IS 50S.F.?. REVISE TRIBUTARY AEA AS REQUIRED BY |
| FOOTNOTES ON TABLE R301.2(2) OF 2010 FBC-RESIDENTIAL. |
| REVISE THE DESIGN PRESSURES ON SHEET S-5 ACCORDINGLY. |
| (4) ROOF ZONE #3 IDENTIFIED ON THE PLAN SKETCH IS |
| WRONG. SEE FIGURE R301.2(7) OF 2010 FBC-RESIDENTIAL AND |
| REVISE AS REQUIRED. |
| |
| |
| B) DESIGN LOAD SCHEDULE. CLEARLY SPECIFY ALL LIVE AN |
| DEAD LOADS, INCLUDING THE ATTIC LIVE LOAD AS REQUIRED |
| BY FOOTNOTES ON TABLE R301.5 OF 2010 GBC-RESIDENTIAL. |
| |
| *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| COMMENT TO EXPEDITE THE REVIEW PROCESS.. |
| *** PLEASE REPLACE AND REMOVE ANY REVISED SHEET.. |
| SUBMIT OLD SHEETS FOR REFERENCE. |
| |
| (NOTE: SEE SAMANTHA'S COMMENTS ON DEMOLITION PERMIT |
| #14120500). |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| (561)805-6712 |
| [email protected] |