2014-12-10 06:54:36 | BUILDING PLAN REVIEW |
| REVISION: 14120295 |
| PERMIT: 14011176 (PRIME) |
| ADD: 2836 N. FLAGLER DR. |
| CONT: OWENS WALTER GROUP |
| TEL: (561)856-6655 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: WED. DEC. 10/2014 |
| ACTION: DENIED |
| |
| 1) THE CONTRACTOR SUBMITTED A MIAMI-DADE NOA # |
| 14-0224.03 CERTAIN TEED MODIFIED BITUMEN ROOFING |
| SYSTEMS OVER WOOD DECK. NO SUB-SYSTEM HAS BEEN |
| IDENTIFIED. EACH SUB-SYSTEM HAS ITS OWN PRESSURES AND |
| LIMITATIONS EITHER 7 OR 9. DEPENDING ON WHICH |
| SUB-SYSTEM IS IDENTIFIED ENHANCED FASTENING IN ROOF |
| ZONES 2 & 3 WILL BE REQUIRED. IF LIMITATION # 7 IS |
| IDENTIFIED FOR THE SUB-SYSTEM PICKED THEN RAS 117 |
| CALCULATIONS WILL BE REQUIRED BY EITHER A ARCHITECT OR |
| ENGINEER. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |