2014-12-11 16:43:48 | 777 SOUTH FLAGLER DRIVE - #1800W |
| PERMIT #14120143 |
| MASTER #13120306 |
| REVIEW COMMENTS - FIRE DEPARTMENT |
| |
| A HIGH-RISE BUILDING REQUIRES OCCUPANTS TO HAVE |
| UNRESTRICTED ACCESS TO A MINIMUM OF TWO EXITS AT ALL |
| TIMES. THE CURRENT PLACEMENT OF THE ELEVATOR LOBBY |
| DOORS RESULTS IN COMMON AREAS (RESTROOMS) BEING LOCATED |
| IN THE ELEVATOR LOBBY. OCCUPANTS IN THE RESTROOM AREAS |
| HAVE UNRESTRICTED ACCESS TO ONLY 1 EXIT STAIR. |
| |
| STAIRWELL RE-ENTRY: EVERY DOOR ASSEMBLY IN A STAIR |
| ENCLOSURE SERVING MORE THAN FOUR STORIES SHALL ENSURE |
| RE-ENTRY SHALL BE POSSIBLE ON THE TOP STORY OR |
| NEXT-TO-TOP STORY SERVED BY THE STAIR ENCLOSURE, AND |
| SUCH STORY SHALL ALLOW ACCESS TO ANOTHER EXIT. |
| |
| THE NUMBER OF MEANS OF EGRESS FROM ANY BALCONY, |
| MEZZANINE, STORY, OR PORTION THEREOF SHALL BE NOT LESS |
| THAN TWO, EXCEPT WHERE A SINGLE MEANS OF EGRESS IS |
| PERMITTED PER CHAPTERS 11 THROUGH 43 (NFPA 101 SECTION |
| 7.4). ACCESS TO AN EXIT SHALL NOT BE THROUGH HIGHER |
| HAZARD AREAS OR ROOMS/SPACES SUBJECT TO LOCKING (NFPA |
| 101 SECTION 7.5.2). DOOR LEAVES SHALL BE ARRANGED TO BE |
| OPENED READILY FROM THE EGRESS SIDE. LOCKS IF PROVIDED |
| SHALL NOT REQUIRE THE USE OF A KEY, FOB, ACCESS CARD, |
| TOOL OR SPECIAL KNOWLEDGE OR EFFORT FOR DOOR OPERATION |
| FROM THE EGRESS SIDE (NFPA 101 SECTION 7.2.1.5). |
| |
| NFPA 101 SECTION 3.3.65 DEFINES AN ELEVATOR LOBBY AS, A |
| LANDING FROM WHICH OCCUPANTS DIRECTLY ENTER AN ELEVATOR |
| CAR(S) AND INTO WHICH OCCUPANTS DIRECTLY ENTER UPON |
| LEAVING AN ELEVATOR CAR(S). |
| |
| WESLEY JOLIN |
| ASSISTANT FIRE MARSHAL |
| WEST PALM BEACH FIRE RESCUE |
| [email protected] |
| (561) 805-6730 |
| |