2014-12-29 18:32:44NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK COUNTY
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
 REQUIRED BY THE COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.
  
 2- DESIGNER OF RECORD TO SPECIFY ALL LIVE AND DEAD
 LOADS, INCLUDING THE ATTIC LIVE LOADS REQUIRED BY TABLE
 R301.5 OF 2010 FBC-RESIDENTIAL. NOTE: CONSIDER THE
 ATTIC WITH PULL DOWN STAIRS ON MOTHER'S IN LAW
 APARTMENT AND SEE ATTIC ACCESS SPECIFIED FOR THE MAIN
 HOUSE.
  
 3- SPECIFY SIZE AND LOCATION OF ATTIC ACCESS FOR MAIN
 HOUSE. SEC. R807 OF 2010 FBC-RESIDENTIAL.
  
 4- PRECAST LINTEL NOA 01-0209.03 SPECIFIED ON THE
 CAST-CRETE TABLE ON SHEET 5 OF 11 EXPIRED ON 5/21/06
 NOT 5/21/15. REVISE AS REQUIRED. DCA RULE 9N-3.
  
 5- WALL SECTION AT ENTRY PORCH ON SHEET 9 OF 11: REVISE
 THE RISER HEIGHT DIMENSION TO COMPLY WITH SEC. R311.7.4
 OF 2010 FBC-RESIDENTIAL.
  
 6- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR ALL
 GUARDRAILS AND HANDRAILS TO SHOW COMPLIANCE WITH THE
 LOADS OF TABLE R301.5 AND THE SPECIFICATIONS OF SEC.
 R312 OF 2010 FBC-RESIDENTIAL.
  
 7- WALL SECTIONS ON SHEET 10 OF 11: E.I.F.S W/ STUCCO
 FINISH NEED TO COMPLY WITH SEC. R703.9.4 AND SEC. R704
 OF 2010 FBC-RESIDENTIAL.
  
 8- WALL SECTIONS ON SHEET 11 OF 11: PROVIDE
 FIREBLOCKING SPECIFICATIONS INCLUDING AREA BETWEEN
 GARAGE AND SECOND FLOOR AS REQUIRED BY SEC. R302.11 OF
 2010 FBC-RESIDENTIAL.
  
 9- PROVIDE MANUFACTURER'S SPECIFICATIONS FOR FOR
 WINDOWS AND DOORS SHOWING THE U-FACTOR AND SHGC FACTOR
 SPECIFIED ON THE ENERGY CALCULATIONS ON ITEM #7. SEC.
 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
 (***NOTE: THIS IS ONLY REQUESTED WHEN THE ENERGY
 CALCULATIONS USE OTHER FACTORS OTHER THAN THE DEFAULT
 FACTORS SET FOR DOORS AND WINDOWS).
  
 10- ENERGY CALCULATIONS: A) PROVIDE THE OWNER'S
 INFORMATION. B) REVISE THE PERMIT OFFICE. THIS IS CITY
 OF WEST PALM BEACH NOT PALM BEACH COUNTY. C) REVISE THE
 JURISDICTION NUMBER. D) REVISE THE ROOF TYPE ON PAGE 2
 OF 6 TO MATCH PLANS. SEC. 103.2.1.1.2 OF 2010
 FBC-ENERGY CONSERVATION.
  
 11- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) OVERHEAD GARAGE DOOR SIZE AS SHOWN ON PLANS. NOA
 12-0110.08 SUBMITTED IS FOR 16'-2" WIDE DOORS.
  
 B) ARCHED ENTRY DOORS SIZE AS SHOWN ON PLANS AND
 ELEVATIONS.
  
 C) HARDIE PLANK SIDING SPECIFIED ON PLANS.
  
 D) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 E) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND ALL DETAILS.. NOTE: PROVIDE ONLY THE COVER SHEET
 AND PAGE SHOWING THE SPECIFIED CONNECTOR OR DESIGNER OF
 RECORD TO WRITE DOWN THE FLORIDA PRODUCT APPROVAL
 NUMBER NEXT TO THE SPECIFIED CONNECTOR.
  
 F) ROOF SHINGLES.
  
 12- DESIGNER OF RECORD TO REVIEW AND APPROVE ABOVE
 PRODUCT APPROVALS. SEC. 107.3.4.1 OF CITY AMENDMENTS.
  
 13- CLARIFY WHERE ARE THE OPAQUE FIBERGLASS DOORS
 FL15037.4 SUBMITTED GOING TO BE INSTALLED?. PLANS AND
 ELEVATIONS DON'T SPECIFY ANY FIBER GLASS DOORS. SEC.
 107.2.1 CITY AMENDMENTS.
 ***NOTE: DESIGN PRESSURES OF FL15037.4 DON'T MEET THE
 CALCULATED DESIGN PRESSURES ON SHEET 2 OF 11..
  
 14- PROVIDE COMPLETE ENGINEERING PACKAGE (SIGNED AND
 SEALED) FOR THE EPICORE CONCRETE FLOOR SYSTEM SPECIFIED
 ON THE FRAMING PLANS. PACKAGE TO BE APPROVED BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL. SEC. 107.2.1.3
 CITY AMENDMENTS.
  
 15- PROVIDE ICC EVALUATION REPORT (OR ANY OTHER AGENCY
 APPROVED REPORT) FOR THE CLOSED CELL ICYNENE INSULATION
 SPECIFIED ON PLANS.
  
 16- DESIGNER OF RECORD TO COORDINATE INFORMATION ON
 PLANS WITH INFORMATION GIVEN ON THE ENERGY
 CALCULATIONS. COORDINATE INSULATION VALUES FOR WALLS,
 CEILINGS, ETC. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 17- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WAS UPDATE TO $643,481. THE
 PERMIT FEE BALANCE IS $10,619.79.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REMOVE AND REPLACE ANY REVISED SHEET.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]