Plan Review Notes
Plan Review Notes For Permit 14110656
Permit Number 14110656
Review Stop B
Sequence Number 1
Notes
Date Text
2014-11-30 15:10:551ST REVIEW: FBC 2010
  
 YOU HAVE PROVIDED DESIGN PRESSURES FOR EXPOSURE C.
 PLEASE PROVIDE DESIGN PRESSURES BASED ON EXPOSURE D:
  
 1609.4.3 EXPOSURE CATEGORIES.
 AN EXPOSURE CATEGORY SHALL BE DETERMINED IN ACCORDANCE
 WITH THE FOLLOWING:
  
 EXPOSURE B. FOR BUILDINGS WITH A MEAN ROOF HEIGHT OF
 LESS THAN OR EQUAL TO 30 FEET, EXPOSURE B SHALL APPLY
 WHERE THE GROUND SURFACE ROUGHNESS AS DEFINED BY
 SURFACE ROUGHNESS B PREVAILS IN THE UPWIND DIRECTION
 FOR A DISTANCE OF AT LEAST 1,500 FT (457 M). FOR
 BUILDINGS WITH A MEAN ROOF HEIGHT GREATER THAN 30 FEET,
 EXPOSURE B SHALL APPLY WHERE SURFACE ROUGHNESS B
 PREVAILS IN THE UPWIND DIRECTION FOR A DISTANCE OF AT
 LEAST 2,600 FEET (792 M) OR 20 TIMES THE HEIGHT OF THE
 BUILDING, WHICHEVER IS GREATER.
  
 EXPOSURE C. EXPOSURE C SHALL APPLY FOR ALL CASES WHERE
 EXPOSURES B OR D DO NOT APPLY.
  
 EXPOSURE D. EXPOSURE D SHALL APPLY WHERE THE GROUND
 SURFACE ROUGHNESS, AS DEFINED BY SURFACE ROUGHNESS D,
 PREVAILS IN THE UPWIND DIRECTION FOR A DISTANCE OF AT
 LEAST 5,000 FEET (1524 M) OR 20 TIMES THE HEIGHT OF THE
 BUILDING, WHICHEVER IS GREATER. EXPOSURE D SHALL EXTEND
 INLAND FROM THE SHORELINE FOR A DISTANCE OF 600 FEET
 (183 M) OR 20 TIMES THE HEIGHT OF THE BUILDING,
 WHICHEVER IS GREATER FROM AN EXPOSURE D CONDITION AS
 DEFINED IN THE PREVIOUS SENTENCE.
  
 ADDITIONALLY, PLEASE INDICATE THE SELECTED PANEL
 WIDTHS, I ASSUME THEY ARE 48". PLEASE INDICATE BY
 MARKING THE PRODUCT APPROVAL OR OTHERWISE. ALSO,
 INDICATE ON THE PRODUCT APPROVAL, OR OTHERWISE, HOW YOU
 FOLLOWED THE INSTRUCTIONS ON SHEET 1 OF 8, AND SHOW THE
 SELECTED ANCHOR OPTION YOU ARE CHOOSING.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved