Plan Review Notes For Permit 14110457 |
Permit Number |
14110457 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2014-11-12 18:30:01 | RESIDENTIAL (R3) WINDOW REPLACEMENT, BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- SPECIFY TYPE AND SIZE OF EXISTING WINDOWS TO BE | | REPLACED TO VERIFY COMPLIANCE WITH THE EGRESS | | REQUIREMENTS OF SEC. 604.1 OF 2010 FBC-EXISTING | | BUILDING. (NOTE: IF THERE IS A CLOSET IN THE OFFICE, | | THEN IT'S CONSIDERED A BEDROOM). DESCRIPTION ON THE | | PERMIT APPLICATION "SIZE FOR SIZE" DOESN'T PROVIDE ANY | | INFORMATION TO DETERMINE IF EGRESS OPENING WAS REDUCED | | NO MORE THAN 5% AS REQUIRED BY SEC. 604.1. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|