2014-11-26 15:51:53 | BUILDING PLAN REVIEW |
| PERMIT: 14110421 |
| ADD: 2711 EXCHANGE CT |
| CONT: TO BE DETERMINED |
| TEL: (561)358-5080 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: WED. NOV. 26/ 2014 |
| ACTION: DENIED |
| |
| 1) THE SUBMITTED PLANS ARE A GOOD BASE FOR THE DESIGN |
| PROFESSIONAL TO TAKE DIMENSIONS FROM AND LAYOUT OF THE |
| TENANT SPACE. THE PLANS ARE COPIES, COPYRIGHT LAWS WILL |
| NOT ALLOW THE ASSUMED WORK OF A DESIGN PROFESSIONAL. |
| THE PLANS DO NOT MEET THE MINIMUM SCALE REQUIREMENTS |
| FOR RECORD RETENSION. |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 107.2.1.4 QUALITY OF |
| BUILDING PLANS. BUILDING PLANS SHALL BE DRAWN TO A |
| MINIMUM 1/8 INCH SCALE UPON SUBSTANTIAL PAPER, CLOTH OR |
| OTHER ACCEPTABLE MEDIUM. THE BUILDING OFFICIAL MAY |
| ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS |
| FOR PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE |
| CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY |
| MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, |
| CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORDS |
| MANAGEMENT. |
| |
| 2) 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING |
| OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA |
| AND DOCUMENTS: |
| 107.3.5.1 COMMERCIAL BUILDINGS: |
| 107.3.5.1.1 BUILDING |
| 1) SITE REQUIREMENTS: |
| PARKING |
| FIRE ACCESS |
| 2) OCCUPANCY GROUP PRIOR AND NEW OCCUPANCY |
| 3) MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED |
| (SEE TABLE 503). |
| 4) FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL |
| INCLUDE THE FOLLOWING COMPONENTS: |
| 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: FIRE |
| SPRINKLERS OR NOT |
| SCHEMATIC FIRE SPRINKLERS |
| 6. LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL |
| INCLUDE THE FOLLOWING REQUIREMENTS: |
| OCCUPANT LOAD AND EGRESS CAPACITIES |
| 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| OCCUPANCY LOAD |
| GROSS |
| NET |
| MEANS OF EGRESS |
| EXIT ACCESS |
| EXIT |
| EXIT DISCHARGE |
| DOORS |
| EMERGENCY LIGHTING AND EXIT SIGNS |
| SPECIFIC OCCUPANCY REQUIREMENTS |
| 10. ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE |
| FOLLOWING: |
| SITE REQUIREMENTS |
| ACCESSIBLE ROUTE |
| TOILET AND BATHING FACILITIES |
| DRINKING FOUNTAINS |
| |
| 3) 2010 EXISTING BUILDING CODE CHANGE IN OCCUPANCY 01.3 |
| CHANGE OF OCCUPANCY CLASSIFICATION. |
| WHERE THE OCCUPANCY CLASSIFICATION OF A BUILDING |
| CHANGES, THE PROVISIONS OF SECTIONS 902 THROUGH 912 |
| SHALL APPLY. THIS INCLUDES A CHANGE OF OCCUPANCY |
| CLASSIFICATION WITHIN A GROUP AS WELL AS A CHANGE OF |
| OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A DIFFERENT |
| GROUP. |
| |
| 4) 2010 FBC-B COMPLY WITH THIS CHAPTER. DAY CARE |
| OCCUPANCIES WILL ALSO NEED TO COMPLY WITH THE 2010 |
| FBC-B CHAPTER 436. |
| |
| 5) 2010 FBC-B EMERGENCY ESCAPE AND RESCUE |
| 1029.2 MINIMUM SIZE. EMERGENCY ESCAPE AND RESCUE |
| OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 |
| SQUARE FEET (0.53 M2). |
| 1029.4.1 |
| EVERY ROOM OR SPACE GREATER THAN 250 SQUARE FEET (23.2 |
| M2) IN EDUCATIONAL OCCUPANCIES USED FOR CLASSROOM OR |
| OTHER EDUCATIONAL PURPOSES OR NORMALLY SUBJECT TO |
| STUDENT OCCUPANCY AND EVERY ROOM OR SPACE NORMALLY |
| SUBJECT TO CLIENT OCCUPANCY, OTHER THAN BATHROOMS, IN |
| GROUP D OCCUPANCIES SHALL HAVE NOT LESS THAN ONE |
| OUTSIDE WINDOW FOR EMERGENCY RESCUE THAT COMPLIES WITH |
| THE FOLLOWING: |
| |
| 1. SUCH WINDOWS SHALL BE OPENABLE FROM THE INSIDE |
| WITHOUT THE USE OF TOOLS AND SHALL PROVIDE A CLEAR |
| OPENING OF NOT LESS THAN 20 INCHES (508 MM) IN WIDTH, |
| 24 INCHES (610 MM) IN HEIGHT, AND 5.7 SQUARE FEET (0.53 |
| M2) IN AREA. |
| |
| 2. THE BOTTOM OF THE OPENING SHALL BE NOT MORE THAN 44 |
| INCHES (1118 MM) ABOVE THE FLOOR, AND ANY LATCHING |
| DEVICE SHALL BE CAPABLE OF BEING OPERATED FROM NOT MORE |
| THAN 54 INCHES (1372 MM) ABOVE THE FINISHED FLOOR. |
| |
| 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 7) A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO |
| HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA |
| TUS.ASPX FOR PERMIT STATUS. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |