Date |
Text |
2014-12-10 07:56:47 | 1ST REVIEW: FBC 2010 |
| |
| FBC 107.3.5.3 PROVIDE A MORE ACCURATE SITE PLAN OR |
| SURVEY TO DEMONSTRATE BUILDING SEPARATION AND PROPOSED |
| ELEVATION. |
| |
| SHEET S-5 CONTAINS ALTERNATE DETAILS AND OPTIONS FOR |
| THE BUILDING ROOF DESIGN. PLEASE SPECIFY THE PROPOSED |
| ROOF DESIGN. |
| |
| SHEET S-5 CONTAINS ALTERNATE DETAILS AND OPTIONS FOR |
| THE BUILDING FOUNDATION. PLEASE SELECT A SPECIFIC |
| FOUNDATION DESIGN FOR THIS SITE AND PROVIDE ADDITIONAL |
| DETIAL TO DEMONSTRATE COMPLIACNE WITH THE FOLLOWING FBC |
| SECTIONS: |
| |
| 1808.7.4 FOUNDATION ELEVATION. |
| ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION |
| SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER |
| AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED |
| DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 |
| PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO |
| THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN |
| BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF |
| DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT |
| ALL LOCATIONS ON THE SITE. |
| |
| 1809.4 DEPTH AND WIDTH OF FOOTINGS. |
| THE MINIMUM DEPTH OF FOOTINGS BELOW THE UNDISTURBED |
| GROUND SURFACE SHALL BE 12 INCHES (305 MM). WHERE |
| APPLICABLE, THE REQUIREMENTS OF SECTION 1809.5 SHALL |
| ALSO BE SATISFIED. THE MINIMUM WIDTH OF FOOTINGS SHALL |
| BE 12 INCHES (305 MM). |
| |
| 2304.11.2.1 JOISTS, GIRDERS AND SUBFLOOR. |
| WHERE WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL |
| FLOOR WITHOUT JOISTS ARE CLOSER THAN 18 INCHES (457 |
| MM), OR WOOD GIRDERS ARE CLOSER THAN 12 INCHES (305 MM) |
| TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED |
| AREAS LOCATED WITHIN THE PERIMETER OF THE BUILDING |
| FOUNDATION, THE FLOOR CONSTRUCTION (INCLUDING POSTS, |
| GIRDERS, JOISTS AND SUBFLOOR) SHALL BE OF NATURALLY |
| DURABLE OR PRESERVATIVE-TREATED WOOD. |
| |
| THE VALUE OF $2,600.00 APPEARS UNDERVALUED. PLEASE |
| UPDATE ACCORDING TO THE SECTION BELOW: |
| FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING |
| PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE |
| TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, |
| ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, |
| RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, |
| MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY |
| LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST |
| PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS |
| SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT |
| VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| |
| |
| STEVEN KENNEDY, CBO |
| CHIEF PLANS EXAMINER |
| (561) 805-6710 |
| [email protected] |
| |