2014-11-08 08:56:39SHEET A1.0: BUILDING PROVISO:
 1) THE BUILDING INDICATES THIS IS A FIRE SPRINKLERED
 BUILDING BUT NO
 PLANS FOR EXISTING AND OR NEW LAY OUT OF SPRINKLERS WAS
 SUBMITTED.
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE,
 CHAPTER 1, ADMINISTRATION:
 107.3.5.1 MINIMUM PLAN REVIEW CRITERIA FOR COMMERCIAL
 BUILDINGS.
 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE:
 SCHEMATIC FIRE SPRINKLERS
  
 2) 2010 FBC-B 13.6 FIRE WALLS, FIRE BARRIERS, FIRE
 PARTITIONS, SMOKE
 BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL
 REQUIRED TO HAVE
 PROTECTED OPENINGS SHALL BE EFFECTIVELY AND PERMANENTLY
 IDENTIFIED WITH SIGNS OR STENCILING IN A MANNER
 ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDENTIFICATION
 SHALL BE ABOVE
 ANY DECORATIVE CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORD-
 ING FOR FIRE AND SMOKE BARRIERS:
 "FIRE AND SMOKE BARRIER , PROTECT ALL OPENINGS"
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  