2015-02-27 14:46:29 | BUILDING PLAN REVIEW |
| PERMIT: 14100651 |
| ADD: 526 NORTHWOOD |
| CONT: K & M CONSTRUCTION |
| TEL: (561)383-2817 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| IMPORTANT NOTICE: EFFECTIVE MAY 11, 2015 |
| ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| ELECTRONICALLY |
| UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| SUBMISSION OPTIONS ARE AS FOLLOWS: |
| 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL |
| SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| NAMING CONVENTION FOR EACH DOCUMENT |
| 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| AVAILABLE |
| |
| 2ND REVIEW |
| DATE: FRI. FEB. 27/ 2015 |
| ACTION: DENIED |
| |
| 1) COMPLIED. |
| |
| 2) 2ND REQUEST, SEMI-COMPLIED. THE PLANS INDICATE A 146 |
| MPH WIND SPEED. THE PLANS DO NOT STATE IF THIS WIND |
| SPEED IS IN VULT OR VASD. THE PRESSURES PROVIDED |
| INDICATES A C EXPOSURE, TAKEN AT 30 FEET AND WORST CASE |
| SCENARIO OR WALL ZONE 5 FOR 10 SQ. FT. THE PRESSURES |
| WOULD EQUATE TO 132 MPH VASD NOT A 146MPH. 2010 FBC-B |
| 1609.1.5 & 1609.1.2.3.1. |
| |
| 3) 2ND REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS. |
| THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE |
| 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| 4A) 2ND REQUEST. SHEET A-3 VARIOUS ELEVATIONS SHOW |
| ORNATE ARCHITECTURAL FACADE WORK, THERE ARE NO DETAILS |
| HOW THE FACADE WILL BE MADE OR SECURED TO THE BUILDING. |
| SHEET A-7 SHOWS NEW COLUMNS, THERE IS A BEAM SCHEDULE |
| THAT STATES POURED, THESE ARE EXISTING BEAMS? THE SUITE |
| 528 SHOWS ON THE FRONT OF THE BUILDING EXISTING BUT THE |
| WEST FACADE DOES NOT STATE EXISTING ON THE FLOOR PLAN? |
| IF THESE ARE TO BE NEW COLUMNS AND BEAMS, THERE SHOULD |
| BE A SHORING PLAN SHOWING HOW THE ROOF FRAMIG ROOF DECK |
| AND EXISTING PARAPET ARE GOING TO BE HELD IN PLACE |
| WHILE THE BEARING WALL IS DEMOLISHED AND REBUILT? |
| |
| 4B) WITH THE WEST ELEVATION WALL BEING REBUILT THE BEAM |
| AND COLUMNS ARE SHOWN BUT THERE IS NO MENTION OF THE |
| STRAPING OF THE 2X10S AND LOADS TO BE TRANSMITTED INTO |
| THE NEW BEAM AND COLUMNS, PART OF THE MWFRS MAIN WIND |
| FORCE RESISTING SYSTEM. 1609.1. |
| |
| 4C) SHEET A-6 WALL SECTIONS SHOW STEM WALL |
| CONSTRUCTION, SHEET A7 NOTES ON THIS SHEET ARE |
| CONFUSSING ON FOUNDATIONS. AT ENTRY AREAS NOTE # 1 |
| ENTRY PIERS MAY UTILIZE P. T. SOUTHERN PINE NO, 2 GRADE |
| 2X6 FRAMING W/ CONCRETE SLAB EXTENSION. A 2ND NOTE |
| BELOW THIS INDICATES: REMOVE PORTION OF SLAB FOR NEW |
| CONCRETE PADS 42X 42X12 INCH W/ #5 6 INCHES EACH WAY. |
| ARE ALL NEW COLUMNS GOING TO RECEIVE NEW FOOTER PADS, |
| WOULDN'T THE ENTRY FRAMING LAND ON THSE NEW PADS, THE |
| HEIGHT OF THE FOUNDATION IS NOT GIVEN? WILL THE STEM |
| WALL CONSTRUCTION TAKE PLACE UNTIL THE HEIGHT OF THE |
| FINISH FLOOR FOR THE COLUMN AND ENTRY PIERS, ONE POUR |
| WITH NO COLD JOINTS? |
| 2114.2 CONCRETE BEARING LEDGE. |
| BRICK, STONE OR OTHER VENEER SHALL BE SUPPORTED BY A |
| CONCRETE BEARING LEDGE AT LEAST EQUAL TO THE TOTAL |
| THICKNESS OF THE BRICK, STONE OR OTHER VENEER, WHICH IS |
| POURED INTEGRALLY WITH THE CONCRETE FOUNDATION. NO |
| SUPPLEMENTAL CONCRETE FOUNDATION POURS WHICH WILL |
| CREATE A HIDDEN COLD JOINT SHALL BE USED WITHOUT |
| SUPPLEMENTAL TREATMENT IN THE FOUNDATION UNLESS THERE |
| IS AN APPROVED PHYSICAL BARRIER. AN APPROVED PHYSICAL |
| BARRIER SHALL ALSO BE INSTALLED FROM BELOW THE WALL |
| SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED |
| IN A MORTAR JOINT. IF MASONRY VENEER EXTENDS BELOW |
| GRADE, A TERMITE PROTECTIVE TREATMENT MUST BE APPLIED |
| TO THE CAVITY CREATED BETWEEN THE VENEER AND THE |
| FOUNDATION, IN LIEU OF A PHYSICAL BARRIER. |
| |
| 4D) TO DATE NO FRAMING DETAILS HAVE BEEN PROVIDED FOR |
| THE COVERED ENTRY. 107.3.5 MINIMUM PLAN REVIEW CRITERIA |
| FOR BUILDINGS. 107.3.5.1 COMMERCIAL BUILDINGS: |
| STRUCTURAL REQUIREMENTS SHALL INCLUDE: WALL/ ROOF |
| SYSTEMS |
| |
| 5) 2ND REQUEST. 107.3.5 MINIMUM PLAN REVIEW CRITERIA |
| FOR BUILDINGS. THE EXAMINATION OF THE DOCUMENTS BY THE |
| BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM |
| CRITERIA AND DOCUMENTS:FLASHING DETAILS AND WILL THERE |
| BE WOOD BUCKS FOR WINDOWS AND DOORS? |
| 1405.12.7 FLASHING. |
| EXPOSED EDGES OF THIN EXTERIOR STRUCTURAL GLASS VENEER |
| SHALL BE FLASHED WITH OVERLAPPING CORROSION-RESISTANT |
| METAL FLASHING AND CAULKED WITH A WATERPROOF COMPOUND |
| IN A MANNER TO EFFECTIVELY PREVENT THE ENTRANCE OF |
| MOISTURE BETWEEN THE GLASS VENEER AND THE BACKING. |
| 1405.13 EXTERIOR WINDOWS AND DOORS. |
| WINDOWS AND DOORS INSTALLED IN EXTERIOR WALLS SHALL |
| CONFORM TO THE TESTING AND PERFORMANCE REQUIREMENTS OF |
| SECTION 1715.5. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |
| |
| |