2015-01-28 10:25:46 | PLAN REVIEW COMMENTS |
| |
| 3RD REVIEW: FBC 2010 |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) (REPEAT COMMENT) THE EXPOSURE CATEGORY WAS CHANGED |
| TO "D" ON THE PLANS, HOWEVER, THE COMPONENT AND |
| CLADDING PRESSURES FOR THE EXTERIOR DOORS AND WINDOWS |
| IN THE SCHEDULE ON SHEET A1.2 WERE NOT INCREASED |
| ACCORDINGLY. FBC-R301.2.1 NOTE: YOU WILL NEED TO REVIEW |
| THE MAXIMUM DESIGN PRESSURES LISTED IN THE PRODUCT |
| APPROVALS FOR THE WINDOWS, DOORS AND OTHER COMPONENTS |
| AND CLADDING PRODUCTS TO MAKE SURE THEY ARE ADEQUATE. |
| SHEET A1.2 IN ONE SET OF PLANS HAS THE OLD EXPOSURE "C" |
| WINDOW AND THE OTHER SET SPECIFIES THAT DOORS AND |
| WINDOWS IN WALL ZONE 4 ARE REQUIRED TO HAVE A -56.5 |
| PSF. THE MAXIMUM DESIGN PRESSURE FOR THE FIBERGLASS |
| DOORS, FL 16674-R3, AND STEEL DOORS, FL10599-R4, ARE |
| BOTH -50 PSF , WHICH IS TOO LOW. PLEASE SUBMIT AN |
| ADDITIONAL SHEET A1.2 WITH THE EXPOSURE "D" PRESSURES |
| AND PRODUCT APPROVALS FOR THE DOORS WITH ADEQUATE |
| MAXIMUM DESIGN PRESSURES. |
| |
| ****PROVISO**** |
| |
| A SIGNED AND SEALED ORIGINAL WILL BE REQUIRED FOR THE |
| *FINISHED CONSTRUCTION* ELEVATION CERTIFICATE PRIOR TO |
| FINAL INSPECTION. |
| |
| BUILDING PHOTOGRAPHS, IN COLOR, WILL BE REQUIRED FOR |
| THE *FINISHED CONSTRUCTION* ELEVATION CERTIFICATE. |
| PHOTOGRAPHS OF ALL FLOOD VENTS, IF INSTALLED, WILL ALSO |
| BE REQUIRED. |
| |
| REVISE THE SITE PLAN (SHEET SP1) TO INCLUDE THE |
| FOLLOWING INFORMATION, FBC 107 |
| |
| REVISE SITE PLAN TO INCLUDE THE NAME(S) OF ADJACENT |
| STREET(S). |
| |
| REVISE SITE PLAN TO INCLUDE ALL DRAINAGE AND UTILITY |
| EASEMENTS. |
| |
| REVISE SITE PLAN TO INCLUDE ALL AREAS TO BE CLEARED, |
| CUT, GRADED, OR FILLED |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |