Plan Review Notes
Plan Review Notes For Permit 14100394
Permit Number 14100394
Review Stop NFIP
Sequence Number 1
Notes
Date Text
2015-01-05 09:40:07****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. REVISE THE ELEVATION CERTIFICATE AS FOLLOWS:
  
 ELEVATION CERTIFICATE PREPARED BY DAVID CUTLER DATED
 10/27/2014, JOB #5061, MICHAEL S. MORANO
  
 A. THE ELEVATION CERTIFICATE PROVIDED AT TIME OF
 APPLICATION FOR THIS PERMIT IS FOR *FINISHED
 CONSTRUCTION* FOR THE EXISTING STRUCTURE. PLEASE
 PROVIDE A *CONSTRUCTION DRAWINGS* ELEVATION CERTIFICATE
 WHICH INCORPORATES PROPOSED CONSTRUCTION ELEVATIONS AS
 WELL AS ADDRESSING THE FOLLOWING:
  
 B. A3, LEGAL DESCRIPTION ON ELEVATION CERTIFICATE IS
 NOT CONSISTENT WITH PROPERTY APPRAISER (SHOULD BE PLAT
 NO. 3). PLEASE ADVISE IF YOU BELIEVE THAT PAPA IS
 INCORRECT.
  
 C. A5, LATITUDE/LONGITUDE COORDINATES ARE TO BE THE
 CENTER FRONT OF THE BUILDING, ACCURATE WITHIN 66 FEET.
 COORDINATES ON EC APPEAR TO BE FOR 122 ARLINGTON PLACE.
  
 D. A5, LONGITUDE COORDINATE IS TO INCLUDE EITHER
 NEGATIVE OR WEST DESIGNATION.
  
 E. B6, INCLUDE FIRM INDEX DATE (3/1/1979).
  
 F. B7, REVISE THE FIRM PANEL EFFECTIVE/REVISED DATE
 FROM 3/1/2079 TO 3/1/1979.
  
 G. C2, BENCHMARK UTILIZED, PLEASE COMPLETE THIS FIELD.
  
 H. C2D, ATTACHED GARAGE IS CURRENTLY 6.8 WITH NO FLOOD
 VENTS. THIS IS TO BE 7.5' OR FLOOD VENTS INSTALLED. THE
 *CONSTRUCTION DRAWINGS* ELEVATION CERTIFICATE SHOULD
 INDICATE PROPOSED CONSTRUCTION (WITH CLARIFICATION IN
 THE COMMENTS SECTION IF NECESSARY).
  
 I. C2E, MACHINERY OR EQUIPMENT IS TO BE AT 7.5'.
  
 J. SECTION D, CHECK BOX FOR COMMENTS.
  
 K. INFORMATIONAL ONLY - SECTION D, A SIGNED AND SEALED
 ORIGINAL WILL BE REQUIRED FOR THE *FINISHED
 CONSTRUCTION* ELEVATION CERTIFICATE AT THE COMPLETION
 OF THE JOB.
  
 L. SECTION D, SEE INSTRUCTIONS; IF LATITUDE AND
 LONGITUDE ARE PROVIDED BY A LICENSED LAND SURVEYOR,
 NOTE HOW THIS INFORMATION WAS OBTAINED IN THE COMMENTS
 SECTION. REVISE COMMENTS TO INCLUDE SOURCE OF LAT/LONG
 COORDINATES.
  
 M. INFORMATIONAL ONLY - BUILDING PHOTOGRAPHS, IN COLOR,
 WILL BE REQUIRED FOR THE *FINISHED CONSTRUCTION*
 ELEVATION CERTIFICATE. PHOTOGRAPHS OF ALL FLOOD VENTS,
 IF INSTALLED, WILL ALSO BE REQUIRED.
  
 2. REVISE THE SITE PLAN (SHEET SP1) TO INCLUDE THE
 FOLLOWING INFORMATION, FBC 107
  
 1. REVISE SITE PLAN TO INCLUDE THE NAME(S) OF ADJACENT
 STREET(S).
  
 B. REVISE SITE PLAN TO INCLUDE ALL DRAINAGE AND UTILITY
 EASEMENTS.
  
 C. REVISE SITE PLAN TO INCLUDE ALL AREAS TO BE CLEARED,
 CUT, GRADED, OR FILLED
  
 D. PROPOSED FFE IS SHOWN AS 7.0'. THE MINIMUM ELEVATION
 FOR THIS STRUCTURE IS 7.5'; PLEASE REVISE. SEE BUILDING
 COMMENTS.
  
  
  
  
  
  
  