Plan Review Notes
Plan Review Notes For Permit 14091088
Permit Number 14091088
Review Stop B
Sequence Number 2
Notes
Date Text
2014-11-08 16:16:50****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. EDGE DISTANCE PROPOSED (2") DOES NOT MEET THE
 REQUIREMENTS OF THE PRODUCT APPROVAL, SEE ANCHOR
 CHARTS. FBC 2010 RESIDENTIAL 301.
  
 2. SHUTTER SPAN STATED IS 100" FOR A 108" HIGH OPENING,
 HORIZONTAL INSTALLATION. ACCORDIONS ARE TYPICALLY
 INSTALLED VERTICALLY, AND SPAN IS BLADE LENGTH. RATHER
 THAN SPECIFYING "WALL" AND "DECO FLOOR", USE THE NAMING
 CONVENTION IN THE PRODUCT APPROVAL (C1 - C5) TO SPECIFY
 WHICH MOUNTING TYPE IS PROPOSED.
  
 3. THE SITE SPECIFIC DOES NOT STATE WIND DESIGN
 CRITERIA, AND THE ENGINEERING IS NOT HIGHLIGHTED OR
 MARKED. REVISE SITE SPECIFIC TO INCLUDE WIND DESIGN
 CRITERIA (WIND SPEED AND EXPOSURE CLASSIFICATION).
  
2014-10-29 15:42:322ND CHECKLIST
  
 1. PROVIDE TWO UP TO DATE SURVERYS SHOWING THE LOCATION
 OF SCREEN WALL.