2014-09-30 16:47:06RESIDENTIAL (R2) FLOORING, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- COPIES OF IMPACT SOUND TRANSMISSION TEST (ASTM E
 492) AND SOUND TRANSMISSION LOSS TEST (ASTM E 90) SHOW
 THAT THE TESTS WERE DONE FOR AN 8" CONCRETE SLAB WITH A
 SUSPENDED CEILING SYSTEM". IF THE PROPOSED INSTALLATION
 DOESN'T MATCH THIS TYPE OF FLOOR/CEILING ASSEMBLY, THEN
 THIS TEST CAN'T BE USED TO SHOW COMPLIANCE WITH THE
 SOUND TRANSMISSION REQUIREMENT OF SEC. 1207 OF 2010
 FBC.
  