2014-12-12 12:26:49****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. ENGINEERING DOES NOT INCLUDE CONSTRUCTION DETAILS
 FOR THE SIGN. GLASS IS SHOWN; NO SPEC FOR GLASS. HOW IS
 THE GLASS SECURED? VERY LITTLE STRUCTURAL INFORMATION
 REGARDING SIGN CONSTRUCTION WAS PROVIDED.
  
 FBC 107, PLANS TO SHOW SCOPE AND NATURE OF WORK. FBC
 1609, PROPOSED IMPROVEMENT TO RESIST WIND LOADS. THERE
 IS A STATEMENT FROM THE ENGINEER THAT THE DESIGN
 RESISTS WIND LOADS BUT NOT ENOUGH INFORMATION WAS
 PROVIDED ABOUT THE SIGN TO CONFIRM THIS. CALCULATIONS
 MAY BE REQUIRED.
  
  
  
  
  