Plan Review Notes For Permit 14090351 |
Permit Number |
14090351 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2014-12-12 12:26:49 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. ENGINEERING DOES NOT INCLUDE CONSTRUCTION DETAILS | | FOR THE SIGN. GLASS IS SHOWN; NO SPEC FOR GLASS. HOW IS | | THE GLASS SECURED? VERY LITTLE STRUCTURAL INFORMATION | | REGARDING SIGN CONSTRUCTION WAS PROVIDED. | | | | FBC 107, PLANS TO SHOW SCOPE AND NATURE OF WORK. FBC | | 1609, PROPOSED IMPROVEMENT TO RESIST WIND LOADS. THERE | | IS A STATEMENT FROM THE ENGINEER THAT THE DESIGN | | RESISTS WIND LOADS BUT NOT ENOUGH INFORMATION WAS | | PROVIDED ABOUT THE SIGN TO CONFIRM THIS. CALCULATIONS | | MAY BE REQUIRED. | | | | | | | | | | |
|