2014-09-24 08:43:20 | BUILDING PLAN REVIEW |
| PERMIT: 14090347 |
| ADD: 771 VILLAGE BLVD. |
| CONT: GREY CONSTRUCTION |
| TEL: (561)312-2766 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: WED. SEPT. 24/ 2014 |
| ACTION: DENIED |
| |
| 1) THE SUBMITTED PLANS ARE PLANS THAT INDICATE THEY ARE |
| 1/4 INCH SCALE THAT WERE REDUCED TO FIT ON 8 1/2X 11 |
| 1/4 PAPER. THEY ARE SMALLER THAN 1/8TH INCH SCALE. THEY |
| COPIES ARE ALSO LIGHT AND WILL NOT BE VISIBLE WHEN |
| SCANNED INTO RECORD RETENSION. THE 3RD ISSUE THE |
| CONTRACTOR OF RECORD GREY CONSTRUCTION WILL NEED TO |
| HAVE THE QUALIFIER PRINT THEIR NAME AND SIGN THEIR |
| PLANS. NOTE A CGC CAN ONLY PREPARE PLANS FOR WHICH THEY |
| ARE LICENSED AND UNDER THEIR SCOPE OF WORK COVERED BY |
| THEIR LICENSE. EITHER PROVIDE THE PLUMBING LICENSE |
| NUMBER OR A PLUMBING CONTRACTOR OR DESIGN PROFESSIONAL |
| ARCHITECT OR ENGINEER FOR THE PLUMBING PLAN. |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION: |
| |
| 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS |
| SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON |
| SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. |
| THE BUILDING OFFICIAL MAY ESTABLISH THROUGH |
| DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND |
| SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS |
| RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH |
| THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR |
| OTHER ITEMS RELATED TO RECORDS |
| MANAGEMENT. |
| |
| 107.3.4 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. |
| 107.3.4.1 GENERAL. WHEN IT IS REQUIRED THAT DOCUMENTS |
| BE PREPARED BY A REGISTERED |
| DESIGN PROFESSIONAL, THE BUILDING OFFICIAL SHALL BE |
| AUTHORIZED TO REQUIRE THE OWNER TO ENGAGE AND DESIGNATE |
| ON THE BUILDING PERMIT APPLICATION A REGISTERED DESIGN |
| PROFESSIONAL WHO SHALL ACT AS THE REGISTERED DESIGN |
| PROFESSIONAL IN RESPONSIBLE CHARGE. IF THE |
| CIRCUMSTANCES REQUIRE, THE OWNER SHALL DESIGNATE A |
| SUBSTITUTE REGISTERED DESIGN PROFESSIONAL IN |
| RESPONSIBLE CHARGE WHO SHALL PERFORM THE DUTIES |
| REQUIRED OF THE ORIGINAL |
| REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. |
| THE BUILDING OFFICIAL SHALL BE NOTIFIED IN WRITING BY |
| THE OWNER IF THE REGISTERED DESIGN PROFESSIONAL IN |
| RESPONSIBLE CHARGE IS CHANGED OR IS UNABLE TO CONTINUE |
| TO PERFORM THE DUTIES. THE REGISTERED DESIGN |
| PROFESSIONAL IN RESPONSIBLE CHARGE SHALL BE RESPONSIBLE |
| FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS |
| PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED |
| SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF |
| THE BUILDING. THOSE PRODUCTS WHICH ARE REGULATED BY DCA |
| RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |