2014-09-19 13:31:41 | COMMERCIAL BUILDING, NEW WINDOW BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE PRODUCT APPROVAL (2COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR THE NEW WINDOWS AS SHOWN ON PLANS | | SUBMITTED. | | | | ***NOTE: WINDOW PRODUCT APPROVAL TO INCLUDE ATTACHMENT | | TO STEEL PLATE AS SPECFIIED BY THE STRUCTURAL ENGINEER | | ON DRAWING S1.0 SUBMITTED. OTHERWISE, SITE SPECIFIC | | ENGINEERING WILL BE REQUIRED. | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) WINDOW PRODUCT APPROVAL AS | | REQUIRED BY SEC. 107.34.1 OF CITY AMENDMENTS TO FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|