Plan Review Notes For Permit 14081033 |
Permit Number |
14081033 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2014-09-15 07:09:15 | 1ST REVIEW: FBC 2010 | | | | THE ARCHITECT OF RECORD SHALL REVIEW THE PROVIDED | | PRODUCT APPROVALS: | | FBC 107.3.4 -WINDOW AND DOOR PRODUCT APPROVAL | | SUBMITTALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 MUST BE REVIEWED AND APPROVED IN WRITING | | BY THE DESIGNER OF RECORD. | | | | THE PLAN HAS BEEN REDLINED TO REQUIRE THE FOLLOWING: | | FBC R703.6.3 WHERE CEMENT PLASTER (STUCCO) IS TO BE | | APPLIED TO LATH OVER FRAME CONSTRUCTION, MEASURES SHALL | | BE TAKEN TO PREVENT BONDING BETWEEN THE CEMENT PLASTER | | AND THE WATER-RESISTIVE BARRIER. A BOND BREAK SHALL BE | | PROVIDED BETWEEN THE WATER-RESISTIVE BARRIER AND THE | | CEMENT PLASTER (STUCCO) CONSISTING OF ONE OF THE | | FOLLOWING: | | 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER | | MATERIAL; OR | | 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER | | OVER AN APPROVED PLASTIC HOUSE WRAP | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|