Plan Review Notes For Permit 14080938 |
Permit Number |
14080938 |
|
Review Stop |
G |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2014-08-26 12:25:40 | 1) SUBMIT MANUFACTURER SPEC. SHEETS FOR THE TANKLESS | | WATER HEATER,RANGE,DRYER, POOL HEATER & FIREPLACE. | | APPLIANCES SHALL BE LISTED AND LABELED PER THE 2010 FGC | | SEC.301.3. | | 2) SUBMIT A CLEAR AND LEGIBLE SURVEY SHOWING THE | | DISTANCE OF THE WATER FROM THE PROPERTY LINES ( SIDE & | | REAR) | | 3) SUBMIT A GAS RISER DIAGRAM SHOWINGTHE LOCATION OF | | SHUTOFF VALVES AND SECOND STAGE REGULATORS AND THE | | LENGTHS OF THE SECTIONS OF PIPE. CITY WPB ADMIN. AMEND. | | TO 2010 FBC SEC.107.3.5.3. (12). | | 4) SUBMIT A COPY OF THE APPROPRIATE TABLE FOR THE CSST | | PIPE FROM THE GAS CODE.SHOW THE CORRESPONDING EHD FOR | | THE CSST ON THE PLAN FROM THE APPROPRIATE GAS SIZING | | TABLE. | | 5) INDICATE THE PSI FOR THE CSST SYSTEM.CITY OF WPB | | ADMIN. AMEND. TO 2010 FBC SEC.107.2.1. |
|