Date |
Text |
2014-09-17 17:51:48 | NEW SIGN BUILDING REVIEW COMMENTS. |
| CODE: 2010 FBC. |
| |
| 1- NEED LICENSE CONTRACTOR TO APPLY FOR BUILDING |
| PERMIT. CHAPTER 489.103 FLORIDA STATUTES EXEMPTIONS |
| REQUIRES AN OWNER BUILDER TO APPLY IN PERSON (SEC. |
| 489.103(7)(C). THE OWNER OF THIS PROPERTY IS A |
| CORPORATION NOT A PERSON. IN ADDITION THE PROPERTY IS |
| FOR THE OWNER'S OWN USE. IT CAN'T BE SOLD OR RENTED |
| (SEC. 489.103(7)(A)1. FL. ST.). |
| |
| 2- SIGN SHALL BE DESIGNED AND CONSTRUCTED TO MEET THE |
| DESIGN PRESSURES OF SEC. 1609 OF 2010 FBC AS REQUIRED |
| BY SEC. 3107 OF 2010 FBC. PROVIDE COMPLETE |
| SPECIFICATIONS FOR THE CONSTRUCTION AND INSTALLATION OF |
| THE SIGN. SPECIFY TYPE AND THICKNESS OF WOOD, SPECIFY |
| TYPE, SIZE (INCLUDING HOW MUCH EMBEDMENT IS REQUIRED |
| INTO THE SUBSTRATE), NUMBER AND LOCATION OF ALL |
| FASTENERS (NOTE: ONLY 4 FASTENERS ARE SHOWN ON PICTURES |
| SUBMITTED). PROVIDE CALCULATIONS SHOWING THAT ONLY FOUR |
| FASTENERS ARE REQUIRED TO MEET THE DESIGN PRESSURES. |
| SPECIFY SUBSTRATE TO WHICH SIGN WILL BE ATTACH TO. |
| SEC. 107.2.1.3 CITY AMENDMENTS TO FBC. |
| |
| 3- PROVIDE NAME AND SIGNATURE OF PERSON RESPONSIBLE FOR |
| THE DESIGN AS REQUIRED BY SEC. 107.2.1 OF CITY |
| AMENDMENTS TO FBC. |
| |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| (561)805-6712 |