Plan Review Notes
Plan Review Notes For Permit 14080263
Permit Number 14080263
Review Stop B
Sequence Number 1
Notes
Date Text
2014-08-07 12:06:10BUILDING PLAN REVIEW
 PERMIT: 14080263/ RE-ISSUE 03020253
 ADD: 1686 39TH ST
 CONT: T. H. MOTTLEY
 TEL: (561)502-1986
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURSDAY AUGUST 07/2014
 ACTION: DENIED
  
 1A) IDENTIFY THE SLOPE OF THE ROOF &, THE MEAN ROOF
 HEIGHT, THE ROOFING PRODUCT APPROVAL SUBMITTED
 02-1205.05 DOES NOT PROVIDE THE TYPE OF FASTENERS IF
 SCREWS OR RING SHANK NAILS INDENTFY, PAGE 4 OR PAGE 5
 IF A ADHESIVE SYSTEM OR MORTAR IDENTIFY SYSTEM AND
 MINIMUM RESISTANCE REQUIED.
  
 1B) IF THE ROOF TILE IS USING A ADHESIVE OR MORTAR SET
 SYSTEM THE TYPE OF UNDERLAYMENT WILL NEED TO BE KNOWN
 IF IT IS A PEEL AND STICK SYSTEM.
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 107.2.1.2 FOR ROOF
 ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION
 DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE
 TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING
 REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE
 RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT
 EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE
 WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  