2014-09-02 12:19:21 | DATE: 9/2/2014 |
| PROJECT: INTERIOR IMPROVEMENTS |
| PERMIT#: 14080234 |
| CODE: 2008 EDITION OF THE NEC |
| 2010 EDITION OF THE FBC |
| 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, |
| ADMINISTRATION, 2012 FBC SUPPLEMENTS. |
| |
| 1ST ELECTRICAL PLAN REVIEW |
| ACTION: DENIED |
| |
| 1) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A |
| PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE |
| ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL |
| DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS |
| LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL |
| 314.3 AND 314.3.1 INDICATE ALL LOCATIONS AND TYPES OF |
| SMOKE/CO DETECTORS REQUIRED BY THE FBC 314 & 315. |
| |
| 2) INDICATE THE TRUE SCOPE AND EXTENT OF ELECTRICAL |
| IMPROVEMENTS. THE APPLICATION STATES "INTERIOR |
| IMPROVEMENTS AND WINDOW REPLACEMENT" THE PLAN PROVIDES |
| AN ELECTRICAL LOAD CALCULATION AND ELECTRICAL NOTES |
| "RECEPTACLE SHALL BE TAMPER RESISTANT", AND "ALL SMOKE |
| DETECTORS SHALL BE INTERCONNECTED" HOWEVER THE LOCATION |
| AND TYPES OF SMOKE/CO DETECTORS IS NOT INDICATED ON THE |
| PLANS. CLARIFICATION ID REQUIRED. INDICATE WHAT IS |
| EXISTING TO REMAIN. WHAT ID REMOVED AND OR RELOCATED |
| AND WHAT IS COMPLETELY NEW OR SIMPLY REPLACED OLD WITH |
| NEW. |
| |
| 2) INDIICATE THE LOCATION OF THE ELECTRICAL PANEL. |
| |
| 3) AN ELECTRICAL PERMIT REQUIRED. |
| |
| 4) |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. SEE LINK: |
| HTTP://WPB.ORG/DEVELOPMENT |
| /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM |
| ITTAL_FORM_04132010.PDF |
| |
| ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO |
| SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED |
| SHEETS FOR COMPARATIVE REVIEW. |
| |
| DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, |
| 561-805-6717 OR [email protected] |
| |