Plan Review Notes
Plan Review Notes For Permit 14080085
Permit Number 14080085
Review Stop B
Sequence Number 2
Notes
Date Text
2014-10-02 15:04:56RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW
 CHECKLIST:
 CODE: 2010 FBC.
  
 1- GARAGE IS CONVERTED TO BEDROOM (SEE BEDROOM
 DEFINITION IN CHAPTER 2 OF 2010 FBC-ENERGY
 CONSERVATION). PLANS NEED TO PROVIDE SPECIFICATIONS
 SHOWING COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC.
 R310 OF 2010 FBC-RESIDENTIAL.
 REPEAT COMMENT. NEED MEANS OF EGRESS. SEE THE
 DEFINITION OF BEDROOM IN THE 2010 FBC-ENERGY
 CONSERVATION. A ROOM WITH A CLOSET IS CONSIDERED A
 BEDROOM. NO HAVING A DOOR DOESN'T EXEMPT IT FROM BEING
 A BEDROOM. (NOTE: AN STUDIO OR A LOFT DON'T HAVE DOORS
 EITHER). REVISE PLANS AS REQUIRED.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR THE NEW EGRESS WINDOW.
  
 3- NEW INSULATION NOTE ON SHEET A-1: PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS SHOWING HOW PROVIDING R-7.8
 INSULATION ON INSIDE OF EXISTING CMU EXTERIOR WALLS AS
 REQUIRED BY SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]