2014-11-21 15:22:29 | BUILDING PLAN REVIEW |
| PERMIT:14071105 |
| ADD: 1517 CAMERON SAMUEL LN. |
| CONT: KAST |
| TEL: (561)346-4994 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2ND REVIEW |
| DATE: FRI. NOV.21/2014 |
| ACTION: DENIED |
| |
| 1A) COMPLIED WITH CORRECTED ADDRESS. |
| |
| 1B) COMPLIED. |
| |
| 2) COMPLIED. NEW SITE PLAN. |
| |
| 3) COMPLIED. 3 ORIGINAL SOILS REPORTS. |
| |
| 4) 2ND REQUEST. COVERSHEET: THE BUILDING CODE ANALYSIS |
| INDICATES THIS BUILDING TO BE A FIRE SPRINKLERED |
| BUILDING. 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR |
| BUILDINGS.:107.3.5.1 COMMERCIAL BUILDINGS: 107.3.5.1.5 |
| . FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: SCHEMATIC |
| FIRE SPRINKLERS. THE DESIGNER OF RECORD HAS TAKEN AREA |
| INCREASES WITH THE INSTALLATION OF A NFPA 13 SYSTEM, |
| 2010 FBC-B 504.2., 903.2.1.2 AND 903.2.1.3. |
| |
| 5) COMPLIED. FITNESS CENTER WITH EQUIPMENT LAYOUT. |
| |
| 6) SHEET A-1.0: |
| 6A) COMPLIED. FIRE BOX SIZING. |
| |
| 6B) 2ND REQUEST. THE THEATER SEATING SHOW RAISED |
| SEATING, THE S6 SHEET SHOWS GEO FOAM NO MANUFACTURERS |
| SPECS WERE SUBMITTED NOR DOES THE PLANS INDICATE THE |
| END OF THE FOAM ARE ENCAPSULATED BY CONCRETE ON THE |
| SIDES. FBC-B 2603.4.1.1. THE STRUCTURAL ENGINEER HAS |
| SHOWN ON SHEET S-6 THE FOAM BEING TOTALLY ENCLOSED. THE |
| CONTRACTOR HAS NOT SUBMITTED PRODUCT TESTING REPORTS |
| AND MANUFACTURERS SPECS FOR THE STRUCTURAL FOAM, NOR |
| HAS IT BEEN REVIEWED BY THE ENGINEER OF RECORD FOR |
| APPROVAL, BY SHOP DRAWING STAMP, APPROVED OR APPROVED |
| WITH COMMENT. |
| |
| 7) COMPLIED. 12/02/14 |
| . THE CONTRACTOR HAS NOT SUBMITTED THE MANUFACTURERS |
| SPEC AND REPORT WHERE THIS PRODUCT CAN BE USED AND |
| LIMITATIONS OF SAID PRODUCT. |
| SHEET A4.1 INDICATES THE USE OF ICYNENE INSULATION AS |
| WELL AS THE COVER SHEET ALSO HAS NOTES FOR ICYNENE. |
| ICYNENE IS TO BE INSTALLED UNDER THE ROOF DECK. PLEASE |
| SUBMIT THE FULL ICYNENE REPORT LISTED ERS 1826 FOR |
| REVIEW; 2010 FBC-B 2603.4.1.6. PLEASE PROVIDE WHICH |
| AREAS ARE GOING TO HAVE ICYNENE TYPE INSULATION AND |
| WHICH AREAS OF THE ROOFING ARE GOING TO HAVE ROOF TOP |
| INSULATION ON TOP OF THE ROOF DECK AS DEPICTED IN |
| DETAILS B-E. THE ENERGY SPECS INDICATE A R-33, PLEASE |
| PROVIDE HOW MUCH INSULATION IT WILL TAKE TO PROVIDE |
| THIS VALUE. |
| |
| . |
| |
| 8) SEMI- COMPLIED. SHEETA-2.2 & A-4.1. SHEET A-2.2 |
| DETIAL # 1 SHOWS THE USE OF 1 INCH RIGID INSULATION |
| BOARD AND THE 5/8 INCH DRYWALL EXTENDING 6 IN. ABOVE |
| THE CEILING LEAVING THE INSULATION BOARD EXPOSED ABOVE |
| THE CEILING. PLEASE PROVIDE COMPLIANCE WITH 2603.4 |
| THERMAL BARRIERS OR 2603.4.1. PROVIDE THE MANUFACTURERS |
| SPEC SHEET FOR THE 1 INCH RIGID INSULATION, INCLUDE |
| FLAME SPREAD & SMOKE DEVELOPMENT. |
| |
| 9A) DEFERRED SUBMITTAL, REQUEST BY THE DESIGNER OF |
| RECORD. |
| MISSING PRODUCT APPROVALS, MAY BE SUBMITTED AS DEFERRED |
| SUBMITTALS UPON WRITTEN REQUEST: |
| 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 |
| COMPONENTS & CLADDING |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| (31)(A) EXTERIOR DOORS. |
| (B) WINDOWS |
| (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| LOUVERS, EFIS SYSTEMS, |
| (D) ROOFING PRODUCTS AND ASSEMBLIES |
| (E) SHUTTERS |
| (F) SKYLIGHTS |
| (G) PRE-ENGINEERED A/C STAND |
| |
| 9B)DEFERRED SUBMITTAL, REQUEST BY THE DESIGNER OF |
| RECORD. |
| 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| 10) NEW COMMENT!!!!! THIS BUILDING QUALIFIES AS A |
| THRESHOLD BUILDING, AN ASSEMBLY OCCUPANCY WITH AN |
| OCCUPANT LOAD GREATER THAN 500 OCCUPANTS & 5,000 SQ. |
| FT. IN AREA. PLEASE SEE NEW COMMENTS THAT WILL BE |
| REQUIRED AS A THRESHOLD BUILDING. THIS MORNING I |
| E-MAILED MATTHEW SLATTER THE REQUIREMENTS FOR A |
| THRESHOLD BUILDING AND FORMS THAT WILL BE REQUIRED TO |
| BE SIGNED. |
| |
| 10A) 109.3.6.1 THE ENFORCING AGENCY SHALL REQUIRE A |
| SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON |
| A THRESHOLD BUILDING PURSUANT TO A WRITTEN STRUCTURAL |
| INSPECTION PLAN PREPARED BY THE ENGINEER OF RECORD. THE |
| STRUCTURAL INSPECTION PLAN MUST BE SUBMITTED TO THE |
| ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING |
| PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING. |
| THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO |
| PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO |
| THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR |
| COMPLIANCE WITH THE PERMITTED DOCUMENTS. |
| |
| 10B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 |
| W.P.B. CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR |
| THRESHOLD BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY |
| FL S S 553.79(5) FLORIDA STATUTES TO THE MINIMUM |
| INSPECTIONS REQUIRED BY THIS CODE. PLEASE FILE OUT |
| FORMS BY ALL INTERESTED PARTIES. |
| CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR |
| PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION |
| BEFORE THE PERMIT MAY BE ISSUED. |
| |
| 10C) THRESHOLD BLDG, REQUIRED STATEMENT: |
| W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING |
| WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE |
| ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT |
| THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S |
| KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE |
| APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE |
| LOCAL AUTHORITY IN |
| ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE. |
| |
| 10D)(1) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR |
| HISTORY FOR THIS TYPE OF CONSTRUCTION. |
| THIS MAY BE SUBMITTED TO KEN CONRAD BY E-MAIL. KEN |
| CONRAD: [email protected] |
| |
| 10D)(2) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A |
| RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. |
| THE RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS |
| SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE |
| WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, |
| AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES |
| WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST |
| MEETING THE ABOVE CRITERIA. |
| CONTACT KEN CONRAD |
| TEL: 561-805-6666 |
| E-MAIL: [email protected] |
| |
| 10E) NOTICE!!!! PLEASE CALL THE CITY OF WEST PALM |
| BEACH?S AUTOMATED TELEPHONE INSPECTIONS LINE (561) |
| 805-6700) FOR IN-PROGRESS INSPECTIONS FOR AUDITING OF |
| JOBSITE INSPECTIONS. |
| |
| |
| 10F) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES |
| FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER |
| HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE |
| MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR |
| WALLS AND CEILINGS. |
| |
| 10G) NOTE SINCE THIS IS A THRESHOLD PROJECT (3) SETS OF |
| PLANS, REPORTS, AND PRODUCT APPROVALS WILL BE REQUIRED, |
| A 3RD SET WILL BE FOR THE THRESHOLD INSPECTORS USE. |
| |
| 11A) NOTICE THIS BUILDING CAN NO LONGER BE CLASSIFIED |
| AS A BUILDING CATEGORY II WITH A OCCUPANT LOAD OF 762 |
| OCCUPANTS. ASCE 7-10 TABLE 1.5-1 RISK AS WELL AS 2010 |
| FBC-B TABLE 1604.5. BUILDINGS FOR PUBLIC ASSEMBLY WITH |
| OCCUPANT LOADS GREATER THAN 300. |
| CATEGORIES LIST THIS AS A CATEGORY III WHICH WILL |
| INCREASE THE PRESSURES SINCE THE WIND SPEED VULT WILL |
| BE 180 MPH. |
| |
| THIS WILL EFFECT SHEET S-6 WITH ALL PRESSUES FLAT ROOF, |
| SLPOED ROOFS (5:12 PITCH) AS WELL AS WALL PRESSURES IN |
| ZONES 4 & 5. PLEASE UPDATE CHARTS. INDICATE IF |
| PRESSURES ARE VULT OR VASD. THERE ARE ALSO PRESSURES |
| THAT ARE TAKEN FROM RAS 128 FOR BUILDINGS THAT ARE LESS |
| THAN 40 FT IN HEIGHT, EXPOSURE "C" FOR A FLAT ROOF, |
| PLEASE NOTE THESE PRESSURES CAN ONLY BE USED FOR |
| BUILDING CATEGORY II BUILDINGS. |
| |
| 11B) SHEET S-6 ALSO IS MISSING THE WALL PRESSURES FOR |
| WALL ZONES 4 & 5. COMPONENTS & CLADDING PRESSURES |
| POSITVE & NEGATIVE TABLE 1609.2(2) . |
| |
| 12-13) COMPLIED. |
| |
| 14) NEW COMMENT: THE COMBINED OCCUPANT LOAD OF |
| BUILDING, POOL AND POOL DECK IS 1,247 SHOW COMPLIANCE |
| WITH: |
| 2010 FBC-B F] 907.2.1.1 SYSTEM INITIATION IN GROUP A |
| OCCUPANCIES WITH AN OCCUPANT LOAD OF 1,000 OR MORE. |
| ACTIVATION OF THE FIRE ALARM IN GROUP A OCCUPANCIES |
| WITH AN OCCUPANT LOAD OF 1,000 OR MORE SHALL INITIATE A |
| SIGNAL USING AN EMERGENCY VOICE/ALARM COMMUNICATIONS |
| SYSTEM IN ACCORDANCE WITH SECTION 907.5.2.2. |
| |
| EXCEPTION: WHERE APPROVED, THE PRERECORDED ANNOUNCEMENT |
| IS ALLOWED TO BE MANUALLY DEACTIVATED FOR A PERIOD OF |
| TIME, NOT TO EXCEED 3 MINUTES, FOR THE SOLE PURPOSE OF |
| ALLOWING A LIVE VOICE ANNOUNCEMENT FROM AN APPROVED, |
| CONSTANTLY ATTENDED LOCATION. |
| |
| 15) ENERGY GAUGE FORM 506-2010 ONLY ONE REPORT WAS |
| SUBMITTED, NOTE THAT THE ENGINEEER SEALED THE REPORT |
| BUT DID NOT SIGN NOR DATE THE REPORT. 61G15-23.002(2) |
| FL. ADMIN. CODE. |
| |
| 16) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |
| |
| |
| |
| |
| |