2014-07-24 08:01:02 | ROOFING PLAN REVIEW |
| PERMIT: 14070650 |
| ADD: 1101 N TAMARIND AVE. |
| CONT: FASTRACK CONSTRUCTION |
| TEL: (561)772-8848 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: THURS. JULY 24/ 2014 |
| ACTION: DENIED |
| |
| 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| 2) TWO (2) ROOFING REPORTS WERE SUBMITTED ONE FOR STEEL |
| DECKS AND ONE FOR A CONCRETE DECK, PLEASE PROVIDE THE |
| CORRECT REPORT, CIRCLE WHICH SUB-SYSTEM WHICH IS |
| INTENDED TO BE INSTALLED. NOTE EACH SUB-SYSTEM HAS HAS |
| LISTED A MAXIMUM DESIGN PRESSURE, SOME HAVE A |
| LIMITATION #7 ( ENHANCED FASTENING) OTHER HAVE A |
| LIMITATION # 9 (MAXIMUM DESIGN PRESSURE). IF ENHANCED |
| FASTENING IS CHOSEN A ARCHITECT OR ENGINEER MUST |
| PROVIDE THE RAS 117 CALCULATION FOR ZONES 2 & 3 |
| .2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.2.1.2 FOR |
| ROOF ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION |
| DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE |
| TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING |
| REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE |
| RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT |
| EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE |
| WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE |
| OR A STATEMENT BY AN ARCHITECT OR ENGINEER FOR THE |
| SPECIFIC SITE MUST BE SUBMITTED WITH THE CONSTRUCTION |
| DOCUMENTS. |
| |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |