Date |
Text |
2014-07-22 07:55:19 | BUILDING PLAN REVIEW |
| PERMIT: 14070606 |
| ADD: 1793 PALM BEACH LAKES SUITE W407 & 408 |
| CONT: TBD |
| TEL: (561)348-4805 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 1ST REVIEW |
| DATE: TUES. JULY 22/2014 |
| ACTION: DENIED |
| |
| 1) PLANS HAVE NOT BEEN REVIEWED & STAMPED BY THE NEW |
| ENGLAND DEVELOPMENT PALM BEACH OUTLET SKYE GROUP TENANT |
| COORDINATOR. |
| TRACY BECKER, TENANT COORDINATOR |
| [email protected] |
| 618-514-2128 |
| |
| 2) THE DESIGNER OF RECORD HAS NOT PROVIDED THE WIND |
| DESIGN CRITERIA AND ASSOCIATED PRESSURES FOR THE NEW |
| STOREFRONT SYSTEM. |
| 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| CHAPTER 6 OF ASCE 7-10. |
| 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| 1609.3 WIND SPEED CONVERSION |
| 2.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN |
| ACCORDANCE WITH 1609.3.1 & ASCE 7-10 |
| |
| 2.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. |
| |
| 2.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| ACCORDANCE WITH 1609.4 & ASCE 7-10 |
| |
| 2.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. |
| |
| 2.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE |
| TABLE 1609.2(2) . |
| |
| |
| 3) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| 1609.6.4.41 COMPONENTS & CLADDING |
| THE SUBMITTED PRODUCT APPROVAL FL16554 WAS SUBMITTED |
| WITH 2 SYSTEMS ,S ERIES 35H & SERIES 50TU, WHICH IS TO |
| BE INSTALLED. |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| (31)(A) EXTERIOR DOORS.YKK AP STOREFRONT SUBMITTED NO |
| SHOP DRAWING STAMP OF APPROVAL FROM THE DESIGNER OF |
| RECORD |
| (B) WINDOWS YKK YHS TECHNICAL SHEETS SUBMITTED, NO FL |
| COVER SHEET, NOR NO SHOP DRAWING STAMP OF APPROVAL FROM |
| THE DESIGNER OF RECORD |
| |
| 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |
| |
| |