2014-07-22 15:14:06RESIDENTIAL (R3) ALTERATION, PLUMBING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- KITCHEN PLUMBING RISER DIAGRAM: THE CLOTHES WASHING
 MACHINE VENTING AND WASTE IS INCORRECT. SEE SEC. P2718
 OF 2010 FBC-RESIDENTIAL AND SEC. P3005.1.1. APPLIANCES
 WITH PUMPING ACTION DISCHARGE CAN NOT BE CONNECTED TO
 THE KITCHEN BRANCH AS SHOWN ON PLUMBING RISER DIAGRAM.
 REVISE AS REQUIRED.
  
 ***NOTE: PLUMBING RISER DIAGRAM MAY BE DRAWN BY THE
 LICENSED CONTRACTOR DOING THE WORK. IF DOING SO,
 CONTRACTOR TO PROVIDE NAME AND SIGNATURE ON PLUMBING
 RISER DIAGRAM.
  