2015-05-22 14:54:54 | 1. PLEASE ADDRESS OUT PREVIOUS COMMENTS FROM THE 2014 |
| REVIEW. |
| |
| 2. GREASE TRAPS ARE PROPOSED WITHIN THE BUILDING, IN |
| THE SAME SPACE INTENDED FOR THE TRASH DUMPSTERS / |
| COMPACTORS. PLEASE VERIFY THAT THE PROPOSED SIZE AND |
| QUANTITY OF TRASH BINS IS APPROPRIATE FOR THE WASTE |
| YARDAGE ANTICIPATED TO BE GENERATED BY THE COMPLEX. |
| DEMONSTRATE THAT THE NEEDED DUMPSTER(S) WILL FIT WITHIN |
| THE PROPOSED BUILDING. CONSIDER USING A COMPACTOR TO |
| REDUCE THE YARDAGE OF WASTE THAT WILL NEED TO BE |
| COLLECTED. (SHEET P101) |
| |
| 3. PLEASE DEMONSTRATE THAT THE PROPOSAL TO ROLL THE |
| TRASH BINS INTO THE ALLEY WILL NOT IMPEDE TRAFFIC FLOW |
| WHILE THE BINS ARE IN THE ALLEY OR COMPLETELY BLOCK |
| TRAFFIC WHEN THE SOLID WASTE TRUCKS ARE COLLECTING THE |
| GARBAGE. |
| |
| 4. PLEASE CONNECT THE FIRE RISER DRAIN TO THE SANITARY |
| SYSTEM RATHER THAN THE STORMWATER SYSTEM. PER NFPA |
| STANDARDS: THE DRAIN SHOULD BE PIPED TO A SUMP, WHICH |
| IN TURN SHOULD DISCHARGE BY GRAVITY OR BE PUMPED TO A |
| WASTE WATER DRAIN OR SEWER. (SHEET FS 201) |
| |
| 5. PLEASE DISCUSS THE PROPOSED SANITARY CONNECTION |
| LOCATION WITH PUBLIC WORKS STAFF. THE CITY IS IN THE |
| PROCESS OF ABANDONING UTILITIES WITHIN ALLEYS DUE TO |
| THEIR AGE AND DIFFICULTY PERFORMING MAINTENANCE AND |
| REPAIR ACTIVITIES. THE SANITARY CONNECTION MAY NEED TO |
| BE RELOCATED TO THE MAIN LINE ALONG DIXIE. |
| |
| |
| KELLY CRANFORD, P.E. |
| LAND DEVELOPMENT ENGINEER |
| PUBLIC WORKS DEPARTMENT |
| CITY OF WEST PALM BEACH |
| [email protected] |