2014-06-24 07:27:40 | PROVISIONALLY APPROVED SUBJECT TO THE FOLLOWING | | FBC-EXISTING BUILDINGS SECTIONS: | | | | 611.1.1 | | NOT MORE THAN 25 PERCENT OF THE TOTAL ROOF AREA OR ROOF | | SECTION OF ANY EXISTING BUILDING OR STRUCTURE SHALL BE | | REPAIRED, REPLACED OR RECOVERED IN ANY 12 MONTH PERIOD | | UNLESS THE ENTIRE ROOFING SYSTEM OR ROOF SECTION | | CONFORMS TO REQUIREMENTS OF THIS CODE. | | | | 611.5 REINSTALLATION OF MATERIALS. | | EXISTING SLATE, CLAY OR CEMENT TILE SHALL BE PERMITTED | | FOR REINSTALLATION, EXCEPT THAT DAMAGED, CRACKED OR | | BROKEN SLATE OR TILE SHALL NOT BE REINSTALLED. EXISTING | | VENT FLASHING, METAL EDGINGS, DRAIN OUTLETS, COLLARS | | AND METAL COUNTER FLASHINGS SHALL NOT BE REINSTALLED | | WHERE RUSTED, DAMAGED OR DETERIORATED. AGGREGATE | | SURFACING MATERIALS SHALL NOT BE REINSTALLED | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|