2014-09-15 16:32:10 | ****CORRECTIONS**** |
| ****THIS IS A FAILED PLAN REVIEW - "N" ENTERED TO ALLOW |
| CARD TO PRINT**** |
| ELEVATION CERTIFICATE FOR 14060942 AND 14050331, |
| PREPARED BY ROBERT J. CAJAL, WALLACE SURVEYING CORP |
| DATED 12/26/13 |
| |
| SAMANTHA HILL |
| BUILDING PLANS EXAMINER |
| [email protected] |
| 561-805-6724 |
| |
| PROPERTY IS NOW OWNED BY 101 CHURCHILL ROAD LLC. AS |
| DISCUSSED, PLEASE HAVE A CONTRACTOR APPLY FOR ALL OPEN |
| PERMITS WHICH WERE OBTAINED UNDER THE FLORIDA STATUTE |
| 489 OWNER BUILDER EXEMPTION. SEE ATTORNEY GENERAL |
| OPINION AGO 91-05. |
| |
| PRIOR TO FORM BOARD INSPECTION ("BUILDING UNDER |
| CONSTRUCTION"), PLEASE CORRECT THE FOLLOWING ITEMS ON |
| THE ELEVATION CERTIFICATE TO AVOID FIELD DELAYS: |
| |
| 1. A1, A2, A3, IT IS MY UNDERSTANDING THAT THIS PARCEL |
| IS UNDERGOING A REPLAT. REVISE THE INFORMATION IN THESE |
| FIELDS IF APPLICABLE. |
| |
| 2. A5, LATITUDE/LONGITUDE DOES NOT APPEAR TO BE |
| CORRECT. THIS IS TO BE ACCURATE WITHIN 66' OF THE |
| CENTER OF THE FRONT OF THE BUILDING. |
| |
| 3. A8C, PLEASE PROVIDE CLARIFICATION ABOUT THE NATURE |
| OF THE FLOOD VENTS AND PROVIDE CALCULATIONS OR |
| INFORMATION AS TO HOW NET OPENINGS HAS BEEN DETERMINED. |
| IN THE PHOTOGRAPH, THE VENT APPEARS BLOCKED. YOU MAY |
| FIND THE FOLLOWING DOCUMENT HELPFUL: |
| |
| TECHNICAL BULLETIN 1, OPENINGS IN FOUNDATIN WALLS AND |
| WALLS OF ENCLOSURES (2008) |
| HTTP://WWW.FEMA.GOV/MEDIA-LIBRARY/ASSETS/DOCUMENTS/2644 |
| |
| VENTS ARE TO BE INSTALLED WITHIN 1' OF ADJACENT GRADE. |
| PLEASE VERIFY WITH PHOTOGRAPHS. ONLY THE PORTION OF THE |
| VENT WHICH IS BELOW THE BFE IS TO BE INCLUDED IN THE |
| NET OPENING AREA. SEE PAGE 19 OF THE TECHNICAL |
| BULLETIN; VENTS THAT CAN BE CLOSED MANUALLY OR THAT |
| HAVE COVERS ARE NOT ACCEPTABLE AS FLOOD VENTS. |
| |
| 4. B1, NFIP COMMUNITY NAME IS "CITY OF WEST PALM BEACH" |
| (REMOVE "UNINCORPORATED"). |
| |
| 5. B6, FIRM INDEX DATE SHOULD BE 03/01/1979. |
| |
| 6. C2E, AS ADVISED DURING PLAN REVIEW, MINIMUM |
| ELEVATION FOR ALL EQUIPMENT SERVICING THE BUILDING IS |
| 7.5'. THE EQUIPMENT WHICH IS CURRENTLY 7.1' WILL BE |
| REQUIRED TO BE RAISED PRIOR TO FINAL INSPECTION. IF IT |
| IS NOT RAISED PRIOR TO FORM BOARD SURVEY/BUILDING UNDER |
| CONSTRUCTION ELEVATION CERTIFICATE, THIS WILL BE A |
| PROVISO ITEM AT THAT TIME BUT WILL BE REQUIRED FOR |
| "FINISHED CONSTRUCTION" ELEVATION CERTIFICATE. |
| |
| 7. PAGE 2, BUILDING STREET ADDRESS, PLEASE REVISE IF |
| ADDRESS OF STRUCTURE HAS CHANGED. |
| |
| |
| |
| |
| |
| |
| |