Date |
Text |
2014-07-07 10:48:58 | 2010 FBC |
| |
| DENIED BY BUILDING |
| |
| 1) THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE WITH A |
| BFE OF 7' NGVD. THE CITY OF WEST PALM BEACH HAS A 6" |
| FREEBOARD, WHICH REQUIRES THE LOWEST FINISH FLOOR |
| ELEVATION TO BE 7.5' BFE OR HIGHER. AN ELEVATION |
| CERTIFICATE WILL BE REQUIRED. |
| |
| 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE |
| REMODELED SPACE AND ADDITION. FBC ENERGY CONSERVATION |
| 401.2 |
| |
| 3) SHOW COMPLIANCE WITH FBCR 314 FOR SMOKE ALARMS THAT |
| MEET THE REQUIREMENT OF THE CURRENT CODE. |
| |
| 4) SHOW COMPLIANCE WITH FBCR 318.6 WHICH REQUIRES |
| GUTTERS WITH DOWNSPOUTS FOR BUILDINGS WITH EAVES OF |
| LESS THAN 6 INCHES HORIZONTAL PROJECTION. |
| |
| 5) SUBMIT TWO COPIES OF THE EVALUATION REPORTS FOR THE |
| SPRAY FOAM INSULATION THAT WILL BE INSTALLED. FBCR 316 |
| |
| 6) SUBMIT TWO COPIES OF THE MANUFACTURER'S |
| SPECIFICATIONS FOR THE LAMINATED VENEER LUMBER (LVL) |
| |
| 7) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE |
| MODIFIED BITUMEN ROOFING MATERIAL AND SIGNED AND SEALED |
| RAS 117 CALCULATIONS FOR ENHANCED FASTENING. ( NOA NO. |
| 13-0424.14 IS SPECIFIED ON PLAN SHEET A.11) DCA RULE |
| 9N-3 |
| |
| 8) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE SLIDING |
| GLASS DOORS, SINGLE HUNG WINDOWS, FRENCH DOORS, SIMPSON |
| HANGERS AND CONNECTORS AS REQUIRED BY DCA RULE 9N-3. |
| |
| 9) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR |
| THE PROJECT. CITY AMENDMENTS 107.4.3.1 |
| |
| 10) SHOP DRAWINGS FOR THE SPIRAL STAIRS THAT HAVE BEEN |
| REVIEWED AND ACCEPTED BY THE DESIGNER OF RECORD ARE |
| REQUIRED TO BE SUBMITTED FOR REVIEW PRIOR TO |
| INSTALLATION. |
| |
| 11) THE VALUE FOR THE SCOPE OF WORK APPEARS TO BE LOW. |
| PLEASE PROVIDE A COST BREAKDOWN OR A COPY OF A SIGNED |
| CONTRACT. CITY AMENDMENTS 109.3 |
| |
| 12) IN ORDER TO SPEED THE PLAN REVIEW TIMES, PLEASE |
| SUBMIT A RESPONSE LETTER THAT INDICATES HOW EACH OF THE |
| REVIEW COMMENTS HAS BEEN ADDRESSED. |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |
| [email protected] |