Plan Review Notes
Plan Review Notes For Permit 14060881
Permit Number 14060881
Review Stop B
Sequence Number 1
Notes
Date Text
2014-08-30 09:58:11BUILDING PROVISO: BEDROOMS MUST MEET THESE
 REQUIREMENTS:
  
 R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED.
 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND
 RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING
 OF 5.7 SQUARE FEET.
 EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM
 NET CLEAR OPENING OF 5 SQUARE FEET (0.465 M2).
 R310.1.2 MINIMUM OPENING HEIGHT. THE MINIMUM NET CLEAR
 OPENING HEIGHT SHALL BE 24 INCHES (610 MM).
 R310.1.3 MINIMUM OPENING WIDTH. THE MINIMUM NET CLEAR
 OPENING WIDTH SHALL BE 20 INCHES (508 MM).
 R313.3 SMOKE ALARMS. LOCATION
 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
 LOCATIONS:
 1. IN EACH SLEEPING ROOM.
 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
  
  
2014-06-20 14:24:39MASTER PERMIT #14050971 BUILDING REVIEW BY SHILL