Plan Review Notes For Permit 14060867 |
Permit Number |
14060867 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2014-07-05 12:28:34 | ****PROVISO**** | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | SEE FLOOR PLAN. FRONT DOOR IS SHOWN AS EMERGENCY MEANS | | OF ESCAPE. IT IS NOT CLEAR HOW THE ACCORDION SHUTTER | | CAN BE OPENED FROM THE INSIDE WITH AN OUTSWING DOOR. | | | | EMERGENCY MEANS OF ESCAPE FBC R310.4 REQUIRED AND IS TO | | COMPLY WITH THE FOLLOWING: | | | | THE MEANS OF ESCAPE SHALL BE WITHIN THE FIRST FLOOR OF | | THE DWELLING OR DWELLING UNIT AND SHALL NOT BE LOCATED | | WITHIN A GARAGE WITHOUT A SIDE-HINGED DOOR LEADING | | DIRECTLY TO THE EXTERIOR. OCCUPANTS IN ANY PART OF THE | | DWELLING OR DWELLING UNIT SHALL BE ABLE TO ACCESS THE | | MEANS OF ESCAPE WITHOUT PASSING THROUGH A LOCKABLE DOOR | | NOT UNDER THEIR CONTROL. | | | | IF THE EMERGENCY MEANS OF ESCAPE SHOWN ON THE PLAN DOES | | NOT COMPLY WITH THIS REQUIREMENT, A REVISION IS | | REQUIRED. | | | | | | |
|