Plan Review Notes
Plan Review Notes For Permit 14060033
Permit Number 14060033
Review Stop B
Sequence Number 1
Notes
Date Text
2014-06-03 10:44:54****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. BUILT UP ROOF NOA PROVIDED. THIS IS TYPICALLY FOR
 FLAT DECKS. IF THIS IS INTENDED FOR USE AS AN
 UNDERLAYMENT FOR THE METAL ROOF, PROVIDE INFORMATION
 FROM THE MANUFACTURER WHICH VERIFIES THAT THIS IS
 ACCEPTABLE FOR USE AS AN UNDERLAYMENT.
  
 IF THIS IS NOT TO BE AN UNDERLAYMENT, AND THERE IS A
 FLAT DECK PROPOSED IN THE SCOPE OF THIS REROOF PERMIT,
 PLEASE SEE THE DESIGN PRESSURE LIMITATION OF -45. AS IT
 REFERS TO GENERAL LIMITATION #9, ENHANCED FASTNING NOT
 PERMITTED. ANOTHER ASSEMBLY IS TO BE SELECTED AND
 ENGINEERING FOR ENHANCED FASTNING PROVIDED.
  
 FBC 2010 RESIDENTIAL 301 (WIND RESISTANCE)