Plan Review Notes
Plan Review Notes For Permit 14050974
Permit Number 14050974
Review Stop P
Sequence Number 1
Notes
Date Text
2014-06-05 19:18:16PLUMBING PLAN REVIEW
 PERMIT: 14050974
 ADD: 525 S FLAGLER DR # GPH3
 CONT: CAMBRIDGE CONSTRUCTION
 TEL: (561)284-3722
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURSDAY JUNE 05/2014
 ACTION: DENIED
  
 1) PLANS SEALED BY OUT OF STATE ARCHITECT. FLORIDA
 ADMINISTRATIVE RULE 61G1-16.002 DESCRIPTION OF SEAL.
 (1) THE SEAL SHALL CONTAIN THE NAME OF ONLY ONE
 ARCHITECT OR INTERIOR DESIGNER AND THE REGISTRATION
 NUMBER; THE SEAL OF THE ARCHITECT SHALL BE CIRCULAR,
 AND THE SEAL OF THE INTERIOR DESIGNER SHALL BE
 HEXAGONAL. BOTH SEALS SHALL BE APPROXIMATELY 2" IN
 DIAMETER WITH TWO CIRCULAR LINES BETWEEN WHICH LINES
 SHALL APPEAR, AT THE TOP, THE WORDS ?STATE OF FLORIDA?
 AND AT THE BOTTOM THE WORDS ?REGISTERED ARCHITECT? OR
 ?LICENSED INTERIOR DESIGNER,? WHICHEVER IS APPLICABLE.
  
 2) SHEETS D-100 & A-100 SHOW THE REMOVAL OF A TUB AND
 NEW LOCATION FOR THE WATER CLOSET & BIDET. THERE IS NO
 FLAT SANITARY NOR SANITARY RISER DIAGRAM SHOWING THE
 NEW SANITARY PIPING AND VENTING OF THESE FIXTURES. 2010
 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION107.3.5 MINIMUM PLAN
 REVIEW CRITERIA FOR BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.3 PLUMBING
 1. MINIMUM PLUMBING FIXTURE CLEARANCES BIDET TO WATER
 CLOSET FBC-P FIGURE 405.3.1.
 2. FIXTURE REQUIREMENTS
 3. WATER SUPPLY PIPING
 4. SANITARY DRAINAGE
 5. VENTS
 6.PLUMBING RISE
  
 3) THE SANITARY WASTE WILL BE ROUTED THROUGH THE FLOOR
 BELOW HOW WILL THE CONTRACTOR GAIN ENTRY. HOW WILL THE
 FLOOR FIRE RATING BE MAINTAINED.
 2010 FBC-P 307.3 PENETRATIONS OF FLOOR/CEILING
 ASSEMBLIES AND FIRE-RESISTANCE-RATED ASSEMBLIES.
 PENETRATIONS OF FLOOR/CEILING ASSEMBLIES AND ASSEMBLIES
 REQUIRED TO HAVE A FIRE-RESISTANCE RATING SHALL BE
 PROTECTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE,
 BUILDING.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved