Date |
Text |
2014-06-23 11:31:04 | PLUMBING PLAN REVIEW |
| PERMIT: 14050913 |
| ADD: 1016 CLARE SUITE # 3 |
| CONT: RIELLY CONSTRUCTION |
| TEL: (561)262-6876 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: MONDAY JUNE 23/ 2014 |
| ACTION: DENIED |
| |
| 1) SHEET P1.1 THE NEW RESTROOM IS NOT DIMENSIONED, |
| COMPLIANCE WITH THE 2010 FBC- ACCESSIBILITY FOR TOLIET |
| ROOM AND 604.3.2 CAN NOT BE DETERMINED. |
| |
| 2) ) SHEET P1.1 ALSO SHOWS A SINGLE WATER FOUNTAIN. |
| PLEASE REVIEW 2010 FBC-ACCESSIBILITY CODE 211.2 MINIMUM |
| NUMBER. |
| NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. |
| ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH |
| 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH |
| 602.7. |
| |
| 3) SHEET P1.1 INDICATES A NEW INSTANTANEOUS WATER |
| HEATER BELOW SINK, THE PLANS DO NOT CALL OUT IF THIS IS |
| THE REQUIRED SERVICE SINK. |
| 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED, & |
| PLUMBING TABLE 403.1. |
| |
| 4) SHEET P0.1 SANITARY RISER DOES NOT SHOW THE WATER |
| CLOSET OR THE SERVICE SINK. SERVICE SINK WILL NEED ITS |
| OWN VENT. FBC-P 907.1. |
| WET VENTS ARE ONLY SUPPOSE TO BE USED IN RESIDENTIAL |
| USE, WITH BATHROOMS BOAF INFORMAL INTERPRETATION # |
| 6090. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |