2014-06-30 08:59:51BUILDING PLAN REVIEW
 REVISION: 14050507
 PERMIT: 13010504
 ADD: 631 EVERNIA ST.
 CONT: MOSS
 TEL: (561
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JUNE 30/ 2014
 ACTION: DENIED
  
 1) THE NARATIVE SHEET LIST SHEETS T-101 & LS-LS101 TO
 BE INCLUDED IN THIS REVISION BUT ARE MISSING. 010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, ADMINISTRATION, 2010 EDITION 107.2.1.3
 ADDITIONAL INFORMATION REQUIRED.
  
 2) SHEET A-203 NEW RECYCLING ROOM (200G) THE LOCATION
 OF THE DOOR TO THIS ROOM BLOCKS THE EGRESS IN IT SWING.
 BECAUSE OF THE DOOR LOCATION THERE IS APPROXIMATLY 19
 INCHES CLEAR WHEN THE DOOR IS OPEN AT 90 DEGREES. THE
 2010 FBC-B 1008.1.9.11
 DURING ITS SWING, ANY DOOR IN A MEANS OF EGRESS SHALL
 LEAVE UNOBSTRUCTED AT LEAST ONE HALF OF THE REQUIRED
 WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY, OR LANDING,
 NOR PROJECT MORE THAN 7 INCHES (178 MM) INTO THE
 REQUIRED WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY OR
 LANDING, WHEN FULLY OPEN. THIS COMMON TO ALL THE
 RESIDENCE FLOORS.
  
 3) PROJECT DOX SHEET NAMING IS MIXED UP FOR SHEET A723,
 THERE ARE 2 SHEETS.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]