Plan Review Notes For Permit 14050113 |
Permit Number |
14050113 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2014-05-14 18:45:09 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE ONE STORY STRUCTURE IS LOCATED IN A 170 MPH VULT | | WIND SPEED AND HAS AN EXPOSURE CATEGORY C. THE MAXIMUM | | DESIGN PRESSURE FOR THE W-45 SYSTEM FROM FL1654-R12 IS | | -90 PSF. THE REQUIRED UPLIFT FOR THE CORNER AREAS IS | | -95.7 PSF. | | | | 2) VALUE OF WORK OF $8000 ON APPLICATION IS LOW. VALUE | | WAS INCREASED FROM $8,000 TO $10,600 BASED ON MARSHALL | | AND SWIFT VALUATION GUIDE. CITY AMENDMENTS 109.3 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|